Removing the Recirculation Pump

IMPORTANT
For this procedure the processor must
be deenergized. See page 1-6. In
addition, the NON DRIVE SIDE
ACCESS PANEL must be removed
from the processor. See pages 1-3
through 1-5 for instructions, if
necessary.
[1]
Disconnect CONNECTOR P/J 7.
[2]
Remove the SPLASH GUARD from over the
RECIRCULATION PUMP.
[3]
Place a CLAMP, TL-2170, on each of the 4
RECIRCULATION TUBES to prevent leakage
of replenishment solution.
[4]
Disconnect each of the 2 RECIRCULATION
TUBES at 2 locations.
[5]
Remove the 2 MOUNTING BOLTS.
[6]
Remove the RECIRCULATION PUMP.
[7]
Install the new RECIRCULATION PUMP.
[8]
Install all parts removed in previous steps.
[9]
Connect the REPLENISHMENT TUBING.
[10]
Connect CONNECTOR P/J 7.
[11]
Check that all cycle speeds are operating
correctly and not producing any error codes.
5-2
RECIRCULATION
PUMP
MOUNTING
BOLT (2)
CONNECTOR
J7
Figure 5-1 Removing the Recirculation Pump