Communications [56]
1=Trigger Events
Once the SIA level has been selected, press
The keypad displays the trigger, the trigger status and the groups assigned.
Select the trigger to be modified using
displayed. Press
ent
1=Status
Set the status to 1=ON or 0=OFF. To accept the new status, press
2=Groups
Use this option to assign groups to each event trigger. To assign or unassign a
group from a specific trigger press the number key corresponding to the group
number. The display shows the new status. To accept the new status, press
2=Groups Setting
Each of the events is signalled to Primary IP/Port Numbers programmed in option 56.4.02.2
and the account number programmed in 56.4.02.4. However, each group can be
programmed to transmit event details to a unique IP address and port number, with a unique
account number.
On selecting this option the first group is displayed. Select the group to be modified, and
then press
. Select one of the following options:
ent
1=Account No.
By default the account number programmed in option 56.4.02.4 is
displayed. Erase the old number, enter a new number (4 to 6 digits), and
then press
2=IP Address
By default the IP address programmed in option 56.4.02.2.1 is displayed.
Erase the old address, enter a new address, and then press
3=Port No.
By default the port number programmed in option 56.4.02.2.2 is
displayed. Erase the old number, enter a new number, and then press
ent
Alarm Reporting Microtech Format [56.4.02.1.2]
Microtech format is a protocol that transmits detailed point ID information to a computer
that has the Alarm Monitoring application installed and running.
The level of information supplied is similar to SIA level 3.
The menu structure and programming of the options are identical to the SIA format. Refer to
Alarm Reporting SIA (0-4) Format [56.4.02.1.1] for programming details.
Alarm Reporting Primary IP [56.4.02.2]
The Primary IP defines the receiver destination details for the primary alarm transmission
path. The destination comprises an IP address and a port number. If groups are enabled the
information programmed for the primary IP and port numbers is automatically copied to all
groups.
1=IP Address
Enter the IP address of the primary receiver, and then press
144
A
to select this option or scroll to 2=Groups and then press
.
ent
.
Galaxy Flex Installer Manual
.
ent
and
, and then press
B
. The 1=Status option is
ent
.
ent
ent
.
ent
.
ent
.
.
ent

Hide quick links: