Note: The factory default setting allows the timed setting routine to be initiated by entering
a valid type 1 user code (or above) and then pressing
assigned to the Timed Set function. The
to perform another function, or to start the setting routine without a code being
entered.

Part Set [13]

This option operates exactly as the Timed Set option with the exception that only those
zones that have the part attribute enabled are set (refer to Program Zones [52]). All zones
have the part attribute enabled by default. Therefore selecting Part Set from the factory will
set all zones. To exclude zones from the part set, disable the Part attribute.
Note: The factory default setting allows the part setting routine to be initiated by entering a
valid type 1 (or above) user code and pressing
the Part Set function. The
another function, or to start the part setting routine without a code being entered.

Forced Set [14]

Option not available.

Chime [15, Quick Menu 1]

The Chime option allows the user to switch the chime facility on and off. Any zones that
have the chime attribute enabled (refer to Program Zones [52]) momentarily operate
entry/exit horns when opened, and two long tones are emitted.

Instant Set [16]

Selecting this option immediately sets all zones. There is no sounder or exit time.
Note: Zones must be closed to allow the system to set. If any zones are open the exit time
reset feature (detailed previously) is activated.

Silent Part [17]

Selecting this option sets all zones that have the part attribute enabled. It starts a normal
timed exit procedure but exit sounders are not activated. In the event of an alarm occurring
during a Silent Part set (e.g. fire alarm), normal operation will be re-instated.
When group mode is enabled (option [63.1]), no other group setting options are affected.
Note: Zones must be closed to allow the system to silent set. If any zones are open, then
the Exit Time Reset feature (detailed previously) is activated.
Unsetting results in a double beep.
key can be reprogrammed by the engineer
A
key can be reprogrammed by the engineer to perform
B
. By default the
A
. By default the
key is assigned to
B
B
Part Set [13]
key is
A
39