Dual Focus (card held)
If a card has a # assigned to the number, then any card-held function will only work in
conjunction with the PIN from the same user, provided that the PIN has a # assigned also.
The Dual function works in either order, but if you enter the PIN first, you have setting
access only and not menu access. If you present the card first, you have setting access and
menu access (see Codes [42] for programming).
Modify Level [42.1.User code.2]
Each user is assigned an access level that controls which menu options can be accessed. The
programmable levels are from 0 to 6.
6 is assigned to the manager.
7 is assigned to the engineer – this is fixed and cannot be assigned to user codes.
8 is assigned to the remote code. This is fixed and cannot be assigned to the engineer or user
codes. The remote code can only be used via keypads addressed as E.
To assign a level to a user:
1.
Type the level to be assigned.
2.
Press
.
ent
EN50131-1
Level
1
0
2
1
2
2
2
3
2
4
2
5
2
6
3
7
3
8
† No access to menu functions
‡ The manager, engineer and remote codes (the last three codes on the system) have fixed
types which cannot be reprogrammed.
Note: All levels except Guard 0 can change their own PIN.
Level
Access Availability
Guard
Entered into event memory – no other option
Guard
Can only set the system and change own PIN
Caretaker
Can only set and unset the system and change own PIN
Users
Menu options 11 to 19
Users
Menu options 11 to 25
Users
Menu options 11 to 32
Manager
Menu options 11 to 48
Engineer
Menu options 11 to 72
Remote
Menu options 11 to 72
Codes [42, Quick Menu 7]