The Fire-Lite ES-1000X is an addressable FACP (Fire Alarm Control Panel) with a pre-installed communicator card that is compact, cost
effective, intelligent, and has an extensive list of powerful features.The combination of Fire-Lite's newer series devices and legacy 300
Series devices, along with the ES-1000X FACP, offer the latest in fire protection technology. The power supply and all electronics are housed
in a metal cabinet, providing a complete fire control system for most applications. Optional modules, which plug into the main circuit board,
are available for special functions. Available accessories include multi-technology central station communicators, LED, graphic, and LCD
annunciators, reverse polarity/city box transmitter, local and remote upload/download software, and remote power expansion.
The ES-1000XC is a ULC-listed Canadian version of the FACP which offers the same features as the ES-1000X, but is supplied standard
with a dress panel. Refer to "Canadian Option" on page 76 for a full description. Note that all references to Class A, Class B, and Class X for
SLC/Communication circuits in this manual also applies to DCLA, DCLB, and DCLC for Data Communication Link for ULC-S527-19.
The ES-1000XI is a version of the FACP which offers the same features as the ES-1000X, but does not come with the pre-installed commu-
nicator.
NOTE: Unless otherwise specified, the term ES-1000X is used to refer to all versions of the panel.
Inventory
When ES-1000X shipment is received, check that all parts have been included in shipment. The ES-1000X shipment consists of one of each
of the following:
main circuit board with loop card and communicator (The ES-1000XI does not include the pre-installed communicator.)
backbox with door, dress panel, and keypad/display
plastic bag containing screws, cables, ELRs, terminal blocks, etc.
1.1 Features and Options
•
Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Telephone Service) Central Station Communicator
•
Pre-installed SLC loop card
•
Optional SLC-3LS Loop Expander Card to add an SLC Loop (two optional cards max. for a total max. of three loops on the FACP)
•
LiteSpeed™ polling protocol for faster SLC response time
•
SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire (refer to "Wire Requirements" on page 141)
•
Single addressable SLC loop which meets NFPA Class B, Class A, and Class X requirements
•
318 addressable device capacity (159 detectors and 159 control/relay/monitor modules) per loop
•
256 software zones
•
Four (4) Class A or four (4) Class B NAC (Notification Appliance Circuits) circuits - special application power
•
8.0 amps total 24 VDC output circuit current in alarm condition
•
Four programmable function keys for ease of maintenance
•
Two programmable relay outputs and one fixed trouble relay
•
Synchronization output for remote power supply applications (special application)
•
Built-in Programmer
•
80-character LCD display (backlit)
•
Real-time clock/calendar with daylight savings time control
•
History file with 1,000 event capacity
•
Addressable sounder base compatibility
•
Multi-criteria detector (smoke, heat, CO) with programmable response
•
Advanced fire technology features:
Automatic drift compensation
Maintenance alert
Detector sensitivity test capability (NFPA 72 compliant)
Automatic device type-code verification
Point trouble identification
•
Waterflow selection per module point
•
Alarm verification selection per detector point
•
Walktest, silent or audible
•
PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)
•
Silence inhibit timer option per NAC
•
Autosilence timer option per NAC
•
Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability
•
Selectable strobe synchronization per NAC
•
Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or ANN-80/ANN-100 Remote annunciator
•
Auto-program (learn mode) reduces installation time. Reports two devices set to the same address
•
Password and key-protected nonvolatile memory
•
User programmable password
•
Fully programmable from local keypad
12
Section 1: Product Description
ES-1000X Series Manual — P/N LS10133-000FL-E:A 6/21/2023