Galaxy Flex Installer Manual
Entry time
The system begins the unsetting routine whenever a final or entry zone activates. The
entry/exit horns pulse slowly indicating that the entry time countdown has started. The user
must go directly to the keypad, using the agreed entry route, and unset the system before the
entry time expires. When 75% of the entry time has elapsed the entry/exit horns pulse
rapidly, indicating that time is running short.
Timeout (slow entry)
If the entry time expires before a valid code is entered to unset the group, a full alarm
occurs. This is recorded in the event log as a Timeout against the group that was in the
process of being unset.
Straying from the entry route
If, during the entry routine, the user strays from the agreed entry route and activates a zone
in a protected area, a full alarm occurs.
Abort time
If a user exceeds the entry time or strays from the entry route a full alarm occurs. However
the activation of the intruder output can be delayed to allow time for the user to abort the
remote signalling.
The Abort Time parameter can also be programmed so that an Intruder alarm is activated
when the entry time expires or a zone is activated, but entry of any valid code cancels the
alarm and deactivates the Intruder outputs without the need for a system reset.
Abort setting message
Zones that are open or opened during the exit period are indicated to the user by a rapid
audible tone from the entry/exit horns. The keypad displays the open zones and then
prompts the user to abort the setting by pressing
users from re-entering the building, closing the open zones, allowing the system to set and
trapping the user in the building.
Fail to set
Option Program Outputs [53], output function 40, Fail Set can be set to activate if a full set
has not occurred after a programmed period of time from the start of the setting procedure,
determined by option Fail to Set [51.35].
Power failure while system is set
When power is restored to the system, following a mains (a.c.) and standby battery (d.c.)
power failure, the system to returns instantly to the set status – full or part – prior to the
power failure.
2 Groups not set
[<],[>] to view
. This message is designed to prevent
esc
Setting features
37