Program Zones [52]
Attributes
On entering programming mode for a zone as described above, use
attribute, or enter an attribute number directly, and then press
Press
to save the programming and return to the attribute selection level.
ent
Press
at any time when assigning attributes 1 and 3 to 13 to abort programming and
esc
return to the attribute selection level. When the attribute is 2=Descriptor the assigned alpha-
numeric text is saved.
1=Function
The Function attribute displays the address and the current function of the selected zone
along with the zone function reference number. You can scroll through the zone functions or
you can enter a zone function reference number directly, for example, enter 19 to display
zone function 19=FIRE. For zone function details, see the Zone Function menu on page 95
and subsequent pages.
Once the required zone function is displayed, press
2=Descriptor
Use this attribute to add an alpha-numeric descriptor of up to 16 characters to a zone. You
can use the inbuilt character set and/or library options.
When you enter the attribute, the current descriptor (blank by default) is displayed on the top
line and an underscore shows where the next character will be positioned. A selection of the
alphabet is shown on the bottom line and the cursor flashes on the letter L.
Press
to erase the characters already assigned to the descriptor.
Use
or
to move the alphabet left or right until the required character is positioned
A
B
underneath the flashing cursor. When the required character is in position press
the character to the descriptor on the top line. Repeat this procedure to assemble the required
zone descriptor.
Text Case and Library
When you enter the attribute the alpha-numeric characters are presented in upper case. Press
to toggle the characters to lower case.
#
Press
when the lower case alphanumeric characters are displayed to toggle to the library
#
words. Use
or
to scroll through the words, or enter a reference number directly (see
A
B
Appendix A: Library). When the required word is displayed, press
descriptor.
Note: Library words are a maximum of 12 characters and upper case only.
3=Chime
Enable the Chime attribute to make a zone chime momentarily whenever it is opened while
the system is unset. The Chime attribute defaults to 0 (disabled) for all zone functions.
Use
or
to toggle the status of the Chime attribute, and then press
A
B
programming.
90
Galaxy Flex Installer Manual
or
A
.
ent
to assign it to the zone.
ent
to copy it to the
ent
ent
to scroll to an
B
to copy
ent
to accept the