Program Zones [52]
When the system is unset operation is identical to the Security zone function.
Pressing
when programming a Secure Final zone doubles the entry time of the group.
Opening a Secure Final zone during the exit time is reported on the keypad as an open zone
and the entry/exit horns bleep rapidly to indicate that the zone is open.
The termination feature of a Secure Final zone can be extended to terminate the setting of
multiple groups by pressing
Group Function.
11 Part Final
This zone has dual functionality:
When the system is full set operation is identical to the Final zone function.
When the system is part set operation is identical to the Intruder zone function.
Pressing
when programming a Part Final zone doubles the entry time of the group.
Opening a Part Final zone during the exit time is reported on the keypad as an open zone;
the entry/exit horns bleep rapidly to indicate that the zone is open.
12 Part Entry
This zone has dual functionality:
When the system is full set operation is identical to the Exit zone function.
When the system is part set operation is identical to the Entry zone function.
Pressing
when programming a Part Entry zone doubles the entry time of the group.
13 PA
The PA (Personal Attack) function is continuously operational. Activation of this zone type
overrides the Bell Delay parameter and causes an instant full alarm condition. A PA Reset
authorized code is required to reset the condition (refer to Parameters [51], 22=PA Reset).
Intruder outputs are not activated by PA zones.
Note: If a PA zone is open, it is indicated on the keypad whenever a valid code is entered.
The group that the open PA is assigned to cannot be set until it is closed.
14 PA Silent
The PA Silent function is identical to the PA function, with the exception that there is no
audible or visible indication of the activation; that is, no bells or strobes are activated. Only
the PA output (normally channel 2 on the digital communicator) signals the alarm. The
activation (+) and restoral (–) of PA Silent zones is recorded in the event log.
Notes:
1.
At the time of setting, any PA Silent zones that are currently open are reported to the
user.
2.
Engineer mode cannot be exited if a PA Silent zone is open.