Appendix G: Peripherals
2.
Plug one end of the connecting cable (B) into the portal, and then plug the other end
into the control PCB.
Configuration
When you have wired a portal, restart the system or exit engineer mode. The system
automatically recognises the new module.
Virtual RIOs
The system assigns virtual RIOs so it can allocate zones for wireless detectors. Please note
the following:
Virtual RIO addresses are not related to RF Portal addresses.
The virtual RIO address will be the next available address on the system.
The system initially allocates two virtual RIO addresses when an RF Portal is
configured.
You can manually alter the number and addresses of the virtual RIO using the RF Address
[51.60.1] menu option.
You can view the zones allocated to wireless detectors using the RF Zones [52.2] menu
option.
Programming
Program wireless zones using the RF Zones [52.2] menu option.
If required customise operation of the wireless system using the RF Parameters [51.60]
menu option.
Use the Display Zones [21] menu option to see the address and signal strength of a wireless
device.
Use the Latest [61.1] menu option to access additional diagnostic features.
Compliance
This product is suitable for use in systems designed to comply with EN50131-5-
3:2005+A1:2008
Security Grade – 2
Environmental Class – II
Independently tested to EN50131-5-3 at Telefication bv, The Netherlands and CNPP,
France