Honeywell Galaxy Flex Installer Manual page 114

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Galaxy Flex Installer Manual
Program Outputs [53]
41 Duress (Latch)
This function is activated by any code assigned as a Duress Code using Codes [42]. The
output is not subject to the Re-arm parameter. It latches on and remains active until a valid
code (type 2 or above) is entered.
42 Illegal Code (Latch)
This output is activated 60 seconds after a single Dual Code entry or a code entry without
the Timer A and/or Timer B times assigned to it (refer to Schedule [42.1.4]).
44 Abort (Latch)
This output is activated after a valid code entry during the Abort period on system entry.
45 Unset
This output is activated each time the system (or group) is unset. The default output mode
attribute is programmed as pulse, for two seconds. This can be used to activate a buzzer to
notify a user that the system has been unset, when using an RF fob.
46 Set Late (Latch)
This output is activated if the system has not been set by the programmed Monitor time
(refer to Status [65.3.1]).
47 U/S Early (Latch)
This output is activated if the system has been unset before the programmed Monitor time
(refer to Status [65.3.1]).
48 Prewarn (Reflex)
This output is active during the programmed pre-warning period of the autoset function. The
mode is Reflex. The Prewarn emits a constant tone if the auto setting of the system can be
extended. If an extension is not possible, Prewarn outputs pulses.
49 Autoset (Reflex)
This output is activated when the system has been set by the autoset function (refer to
Autoset [65.3]). The default Output Mode attribute is programmed as Reflex, therefore the
output remains active until the system unsets.
Note: The Set is also activated when the system autosets.
51 – 55 Link A – E (Reflex)
Link outputs have no inherent function. They are designed for use with Links [54] to
provide the engineer with a means of activating a specific output address. Link outputs can
be activated by any of the link option sources. The operation of the Link output is dependent
on the Output Mode and Groups assigned to the output. The Groups assigned to the Link
must have at least one group common to the link output if that output is to be activated. This
feature can be used to multiply the number of different link outputs available on the system.