Honeywell Galaxy Flex Installer Manual page 173

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Galaxy Flex Installer Manual
Use the
or
keys to select the required day or days and press
A
B
programming and return to the previous menu level:
1=MON; 2=TUE; 3=WED; 4=THU; 5=FRI
Timer Outputs [65.2]
Once the times have been programmed and the Status is set to 1=On, the Timer-A or Timer-
B outputs types 29 and 30 are activated at the On times and deactivated at the Off times
programmed in Weekly Schedule [65.1]..
Autoset [65.3]
Each group can be programmed with up to 42 Autoset events over a 7 day period. These can
be combined in any order of On and Off times as required.
When the system has been set by the Autoset function, outputs programmed as Autoset are
activated (refer to Program Outputs [53]); the Set outputs are also activated.
Programming Autoset
If groups are enabled (refer to Options [63]) the keypads prompts for the group that the
autoset time is to be allocated to. Press
number is displayed and press
Account Group Autosetting
Account Group autosetting is allowed. This means that several groups can be bound together
into one account group and, instead of a sending a normal CA (closed automatically) event,
the panel sends a CL (closed late) event.
Refer to Account No [56.1.2.2.2].
There are five stages to programming the Autoset function:
Autoset Status [65.3.1]
0=Off (default)
1=On
2=Monitor
If selected, the setting and unsetting of the group is monitored:
If not set manually before the On time, then the Set Late output is activated.
If unset before the Off time, then the Unset Early output is activated.
Prewarning [65.3.2]
1=Period 0 – 50 minutes (default 30 minutes)
2=Audible (this can be turned ON or OFF)
Use this option to set the warning period given to users prior to the system autosetting.
Outputs programmed as Pre-warning activate during the pre-warning period. The output
normally emits a constant tone, however if an extension is not possible, then a pulsed tone is
or
to step through the groups until the required
A
B
.
ent
Timers [65]
to accept the
ent
173

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents