Rio Wired Zone/Output Expander - Honeywell Galaxy Flex Installer Manual

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Galaxy Flex Installer Manual

RIO wired zone/output expander

A RIO wired zone/output expander provides 8 programmable zones and 4 outputs.
Note: A Power RIO can be fitted in place of a RIO.
The RIO requires 12 V d.c. (range 10.5 V to 16.0 V) and 40 mA. This can be supplied from
the control panel power supply or from a remote power supply if the distance causes a large
voltage drop on the cable.
Wiring
1.
On a keypad, enter engineer mode before connecting the RIO.
2.
Connect the RIO terminals as follows:
RIO terminals
+12 V
–0 V or ground
A
B
Note: If the RIO is the last module on the line, connect a 680
the
and
A
Configuration
To configure the RIO in the system, exit from engineer mode. If the message XX Mod
Added [<],[>] To View is displayed, the system has recognised the module. Press
confirm that the RIO has been added. If the message is not displayed or the RIO is not on
the list of added modules, then it is not communicating with the control panel or has been set
to the same address as a RIO already connected to the system.
The flash rate of the red LED (LED 1) indicates module to panel communication status.
Flash rate (secs)
0.1 on / 0.9 off
Off
1.5 on / 1.5 off
0.2 on / 0.2 off
0.9 on / 0.1 off
Zones
The RIO has eight programmable zones that default to INTRUDER. Each zone is Double
Balance monitored with a 1 k resistor in series with the zone detector and a 1 k (1%)
resistor in parallel across the detector switch. The change to 2 k (1%) resistance registers
the zone as open/alarm.
Connection point
control panel, keypad or remote power supply
control panel, keypad or remote power supply
A terminal of the previous module on the line or control panel if the RIO is the
first on the line
B terminal of the previous module or control panel if the RIO is the first on the
line
terminals.
B
Meaning
Normal communications
No d.c. supply
RIO has not been configured into system
RIO has lost communication with system
Very poor communications
Appendix G: Peripherals
EOL resistor across
or
to
A
B
219

Hide quick links:

Advertisement

Table of Contents
loading