Wire detectors to zones

2.
Connect an RS485 data cable between the panel and each device in a daisy-chain
configuration, using the information in the tables below.
Note: Do not use spur and star configurations.
We strongly recommend you use a twisted-pair screened cable (Belden 8723
equivalent, Cat 5/5e). However, for cable runs of less than 100 m in normal
environments, standard 4-core cable can be used.
Panel Keypad/
Keyprox
+12 V
+
GND
A
A
B
B
* Do not connect power supplies in parallel. Do not connect +12 V terminals between
the control panel and remote power supplies. However, connect the 0 V (negatives)
of all power supplies at a common reference point.
Wire detectors to zones
Note: Learning wireless detectors is covered on page 20.
Zones are the individual input circuits that are fully programmable using the Zones menu
(
). This section describes how to change zone default settings, how to terminate
52 ent
unused zones, and how to connect detectors.

Zone addressing

The zone address format is:
The RIO address range is 00 to 12, and each RIO can handle up to 8 zones.
Note: 00 and 01 are the fixed onboard RIO addresses.
Address onboard zones as follows:
If required, use the Descriptor menu (
16
TouchCenter RIO/DCM PSU
+
Vin
G
A
Y
B
Zone
Address
1
1001
2
1002
3
1003
4
1004
5
1011
6
1012
52 ent 2 ent
Galaxy Flex Installer Manual
Audio
Telecom Ethernet
Interface
X*
+12 V
+12 V
0 V
GND
-
A
A
A
B
B
B
Zone
Address
7
1013
8
1014
9
1015
10
1016
11
1017
12
1018
) to name your zones.