Remote Access [47]
Auto Service Mode Confirm [47.4.1.3]
In this mode, when you exit from engineering mode following a change to the panel
programming, you are prompted to initiate a remote connection. This must be authorized by
an appropriate user type before the call is made.
Once authorized, a two minute delay period is initiated. During this period, you can initiate
or cancel the call.
When a connection is initiated the panel uploads the new panel programming to the remote
servicing package.
Auto Service Timers Start Time [47.4.2.1]
Set the start time of the off-peak window during which the panel can initiate an automated
remote servicing call. The default is 01:00.
Auto Service Timers End Time [47.4.2.2]
Set the end time of the automated remote servicing call during the off-peak window. The
default is 06:00.
Auto Service Timers Sync Schedule [47.4.2.3]
Use this option to program the panel to automatically connect to the remote servicing
application and upload the latest panel programming during the off-peak window. The
period of time between connections can be set from 0 to 365 days. The default setting is 0,
which disables the option.
The off-peak time window is programmed in menus 47.4.2.1 and 47.4.2.2.
Auto Service Timers Schedule Reset Off [47.4.2.4.0]
The panel never initiates a remote servicing connection. This is the default setting.
Auto Service Timers Schedule Reset Auto [47.4.2.4.1]
Use this option to reset the Sync Schedule timer after an automated connection.
Auto Service Timers Schedule Reset Manual [47.4.2.4.2]
Use this option to reset the Sync Schedule timer, after a copy of site data whether done
automatically or manually.
Auto Service Terminate Idle [47.4.3]
Use this option to program a timeout period that terminates a remote connection after the
programmed period of activity. The range is 0 to 60 minutes, and the default timeout period
is 10 minutes. After termination the panel records in the event log the message REM
ABORT to indicate that the connection was unexpectedly terminated.
Conn. Retry Interval [47.4.4.1]
Use this option to program the dial attempts from 0 to 60 minutes. The default setting is 30
minutes, and 0 disables the feature.