Honeywell Galaxy Flex Installer Manual page 82

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Parameters [51]
To select a preset, enter an option number from the tables below, which show the resistance
windows for each type:
Option 01
1k
Tamper S/C
0 - 800
Low Res
800 - 900
Normal
900 - 1200
High Res
1200 - 1300
Open
1300 - 12000
Fault
-
Masked
12000 - 19000
Tamper O/C
19000 - infinity
Table 1 Preset value limits (ohms) - double balanced
Option 02
1k
Tamper S/C
0 - 800
Low Res
800 - 900
Normal
900 - 1200
High Res
1200 - 1300
Fault
-
Masked
1300 -19000
Open
19000 - infinity
When a preset is selected it sets the zone resistance range used by every zone on the system.
Each zone on the system can be further customised to a specific preset by using the
Resistance Select [52.9] option.
Set Confirm [51.47]
Use this option to cause the system to emit a short double beep when the system/group has
set. There are three options:
0=Off
1=Alert on Set
2=Alert on Comm
Alarm Limits [51.48]
Use this parameter to program the maximum number of alarms, per group, which may be
transmitted to an Alarm Receiving Centre in any set period. There are three options:
82
Option 03
Option 05
2k2
4k7
0 - 1800
0 - 3700
1800 - 2000
3700 - 4200
2000 - 2500
4200 - 5500
2500 - 2700
5500 - 6500
2700 - 12000
6500 - 12000
-
-
12000 - 19000
12000 - 22000
19000 - infinity
22000 - infinity
Option 04
Option 06
2k2
4k7
0 - 1800
0 - 3700
1800 - 2000
3700 - 4200
2000 - 2500
4200 - 5500
2500 - 2700
5500 - 6500
-
-
2700 - 19000
6500 - 22000
19000 - infinity
22000 - infinity
Table 2 Preset value limits (ohms) - end of line
No indication.
A double beep when the system has set.
A double beep after a successful signal to the ARC that setting has
occurred.
Galaxy Flex Installer Manual
Option 07
Option 09
5k6
3k3
0 - 1400
0 - 2600
1400 - 2800
2600 - 3000
2800 - 8400
3000 - 4000
8400 - 9800
4000 - 4400
9800 - 12600
4400 - 12000
-
-
12600 - 25000
12000 – 22000
25000 - infinity
22000 - infinity
Option 08
Option 10
5k6
3k3
0 - 1400
0 - 2600
1400 - 2800
2600 - 3000
2800 - 8400
3000 - 4000
8400 - 9800
4000 - 4400
-
-
9800 - 25000
4400 - 19000
25000 - infinity
19000 - infinity
Option 11
Option 13
1k fault
1k N/O
0 - 800
-
800 - 900
-
900 - 1200
1200 - infinity
1200 - 1300
-
1300 - 3500
0 - 1200
3500 - 4500
-
4500 - 19000
-
19000 - infinity
-
Option 12
Option 14
1k fault
1k N/O
0 - 800
-
800 - 900
-
900 - 1200
1200 - infinity
1200 - 1300
-
1300 - 4500
-
4500 - 19000
-
19000 - infinity
0 - 1200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents