Install the power supply

Install the power supply
Safety instructions
Fixed wiring and connection to the electricity supply of this product must be carried out and
inspected in accordance with the territorial wiring regulations by a competent person. In the
UK the IEE Wiring Regulations in accordance with BS7671 apply.
A power cord with a fitted plug is supplied. You can, as an alternative, discard the plug and
wire directly to the mains supply via a switched 3 A fused connection. If you do this, read
General Safety below.
You can also connect to the mains supply via a non-time-delayed fuse, or a type B MCB at
the distribution board, not exceeding 6 A. If this method is used, fit an isolation switch near
to the unit to allow disconnection when necessary.
General Safety
The power supply is supplied with a standard plug. In the UK, if you need to change the fuse
in this plug, use a 3 A fuse to BS1362. Always refit the plastic fuse carrier when replacing
the fuse. (Units supplied with a European plug do not have a fuse internal to the plug).
If replacing the plug, follow any instructions that are supplied with the new plug. Connect
the brown wire to the line connector (L) terminal, and the blue wire to the neutral (N)
terminal. Do not connect brown or blue to the earth (E) terminal. This appliance does not
require an earth connection. Dispose of the old plug promptly and safely to avoid the danger
of it being plugged into a live socket.
Parts supplied:
Switched mode PSU with figure-8 a.c. input socket and jack plug output cable
A.C. power cord with 2-pin plug and figure-8 plug
Fused mains terminal block and mounting plate