Parameters [51]
Confirm Reduce Reset [51.55.3]
Use this option to allow user reset following an unconfirmed alarm.
0=Off
1=On Unconfirmed
Timeout Confirm [51.55.4]
Use this option to define if an Entry Time-out alarm will contribute to a confirmed alarm
0=Disabled
1=Enabled
Force Restore [51.56]
Use this option to select when intruder restore signals are transmitted.
1=Unset/Unconfirm
2=System Reset
[51.57] Not used
Power Alarm [51.58]
Enable this parameter to allow the Bells, Strobe and Horn outputs to activate when there is
an a.c. failure and the system is set. The default is 0.
Part Tone [51.59]
Enable this parameter to change the setting tone for a part set. The new tone is on for 2
seconds and off for 0.1 seconds.
RF Address [51.60.1]
Use this option to specify the number of virtual RIO addresses available for wireless
detectors zones. Up to 24 addresses in total can be allocated with a limit of 3 addresses for
each RF Portal configured.
Each RIO address is displayed with E if enabled for wireless or D if disabled. To change the
status, press
.
ent
Select
to disable or
0
be prompted to remove or reassign programmed zones to another RIO address.
RF Fob PA [51.60.2]
Use this option to enable a user to program the Panic Alert function of a wireless keyfob.
Note: In some locations, the Panic Alert function may not be permissible.
84
Full system reset is required for any intruder alarm.
The system can be reset by a user if the alarm is unconfirmed.
If the alarm is classed as confirmed, a full system reset is required.
Time-out will not contribute (PD6662: 2004)
Time-out will contribute (PD6662: 2010)
On unset or at the end of the confirmed time if the alarm is not
confirmed.
Sent when the system is fully reset.