Honeywell Galaxy Flex Installer Manual page 201

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Galaxy Flex Installer ManualAppendix B: SIA and contact ID event codes
Ev
SIA Event
Description
PT
Panic Trouble
PU
Panic Unbypas
Q - Assist (Custom SIA - see note 2)
QA
Alarm
QB
Bypass
QJ
Trouble Rest
QR
Alarm Restore
QT
Trouble
QU
Unbypass
R - Remote, Log, Test
RB
RC
Relay closed
RD
Prog, denied
RO
Relay open
RP
Automatic test
RR
Power Up
RS
Prog, success
RX
Manual test
S - Sprinkler (Custom SIA - see note 2)
SA
Alarm
SB
Bypass
Log
Log Event
Event
Description
LOW RES+
Low resistance on zone
HIGH RES+
High resistance on zone
FORCE OMT-
Unomitted after rearm
Note 1
zone in alarm
OMITTED
zone omitted
FORCEOMT+
Force omit after rearm
LOW RES-
Restor zone resistance
HIGH RES-
Restor zone resistance
Note 1
zone restored
LOW RES+
Low resistance on zone
HIGH RES+
High resistance on zone
FORCE OMT-
Unomitted after rearm
REM LOG
REM RESET
REM ID
REM COPY
REM OVRWR
REM MSG
COPY SITE
OVWR SITE
LINK-
Link zone closed
LOG-
Log zone closed
LOG DELAY-
Log delay zone closed
CUSTOM A-
Zone closed(Non alarm)
CUSTOM B-
Zone closed(Non alarm)
EXITGUARD-
Exitguard zone closed
RMACCESS+
Zone denied rem. acc
BELL FAIL
Bell fail zone opened
KEYSWITCH
LINK+
Link zone opened
LOG+
Log zone opened
LOG DELAY+
Log delay zone opened
NOT USED
SET LOG
CUSTOM A+
Zone opend(Non alarm)
CUSTOM B+
Zone opend(Non alarm)
EXITGUARD+
Exitguard zone opened
PUSH SET
Push set zone opened
KSW RESET
SPARE
Spare zone opened
AUTOTEST
Automatic test
MEMORY OK
Warm start of panel
RM ACCESS-
Zone allowed rem acc
REM CALL
Remote call complete
ENG TEST
Engineer test
Note 1
zone in alarm
OMITTED
zone omitted
FORCEOMT+
Force omit after rearm
Ev Type Trigger
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
ZONE
5.CUS ZON
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
5.CUS ZON
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
MODULE
NONE
MODULE
NONE
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
14.MEN AC
ZONE
16.LOG
KS
NONE
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
NONE
KS
NONE
ZONE
16.LOG
EVENT
ALWAYS TR
EVENT
13.ELEC ST
ZONE
14.MEN AC
MOD
14.MEN AC
USER
ALWAYS TR
ZONE
5.CUS ZON
ZONE
8.OMIT
ZONE
8.OMIT
Contact
ID Event
380
380
573
Note 1
573
573
380
380
Note 1
380
380
573
0
0
0
0
0
0
0
0
150
150
150
150
150
150
553
150
150
150
150
150
150
150
150
150
150
150
150
150
602
305
553
412
601
Note 1
573
573
201