Omit Zones [11, Quick Menu 0]

Menu Options 11-19

Omit Zones [11, Quick Menu 0]
Use this option to remove (omit) zones from the system temporarily. Once a zone has been
omitted it does not generate an alarm condition (including tamper). Omitted zones are
reinstated automatically when the system is unset or reinstated manually when the zone omit
option is disabled.
On selecting the Omit Zones option, the first zone that has the omit attribute enabled is
displayed (refer to Program Zones [52]). If there are no omittable zones, then the message
NO ENTRIES is displayed.
Scroll to the zone you want to omit, and then press
indicates the new omit status.
Note: A zone is omitted from the system as soon as it is selected.
Repeat this process to omit more zones if required, and then do one of the following:
press
to start the timed setting routine. The number of zones omitted from the
ent
system is displayed during the exit time countdown;
to return to 11=OMIT ZONES without starting the setting routine.
press
esc
On returning to the banner (normal or engineer) the keypad displays the message ZONES
OMITTED.
Outputs programmed as Zone Omit (mode programmed as reflex) are activated as soon as
the zone is omitted and remain active until the zone is reinstated.
Manually reintroduce omitted zones
Select the OMIT ZONES option.
Select the omitted zone to be reinstated, and then press
required zone. The display indicates the new omit status.
Normal Setting with omitted zones
Initiate the full or part setting routine. The system starts to set, and the display indicates that
zones have been omitted. The zone remains omitted until the system is unset.

Timed Set [12]

This option starts the setting routine. The entry/exit horns emit the expiry warning using the
programmed exit time (0-300 seconds). The system sets at the end of the exit time or earlier
if a final zone is opened and closed, key 0 is pressed if programmed as an exit terminator, or
if a push-set terminator is operated. The option displays the time remaining until the system
sets or the number of open zones preventing the system from setting. Opening a zone during
the exit routine resets the exit timer. Pressing
setting routine.
38
Galaxy Flex Installer Manual
to toggle the omit status. The display
#
to toggle the omit status of the
#
prior to the system setting aborts the