Engineer 3; Auto Detect [72] - Honeywell Galaxy Flex Installer Manual

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Galaxy Flex Installer Manual

Engineer 3

Auto Detect [72]

Use this option to let the system automatically recognise new and removed modules without
leaving engineer mode.
On entering the option the number of modules on the system is displayed.
In Auto Detect mode the system continuously poles for any new or missing modules. A list
of added or removed module information (address) is displayed for 3 seconds per module.
When a module is removed it is identified as missing and listed, but the now count is not
decreased until you confirm that removal is valid.
When a module is added the now count is increased.
To view all the added or missing modules:
1.
Press
.
esc
2.
Press
or
to scroll through the list.
A
B
To confirm module removal:
Press .
Modules added and removed are recorded in the event log.
To program or configure a new module, exit the Auto Detect option.
Engineering Exit operation and Auto Detect operation are mutually exclusive; when one
operation is initiated or in progress the other can't be initiated.
If you attempt to exit Engineer mode from another keypad while Auto Detect is in operation
the INSUFFICIENT ACCESS RIGHTS message is displayed.
Note: During the auto detection process, you may see a performance delay on other
keypads in the system.
SYSTEM MODULES
was 5 now 5
SYSTEM MODULES
was 5 now 8
Auto Detect [72]
189

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents