Program Zones [52]
33 Custom A
This function allows a zone to be assembled. The functionality of the zone (when it
activates; the outputs activated; if it sets or unsets the systems; if it logs) are assigned using
Assemble Zones [64]. Once the Custom A zone has been created, it can be assigned to as
many zones as required.
34 Custom B
This function is identical in operation and assembly to Custom A.
39 Keyswitch Reset
The Keyswitch Reset function allows alarms to be cancelled and the system to rearm
without unsetting the system. The type of reset authorization is determined by the
Keyswitch Level [51.14]. The type required to reset Intruder, PA and Tamper alarms is
determined by the System Reset, Tamper Reset and PA Reset parameters (options 51.06,
51.07 and 51.22) respectively.
This function is designed to permit a remote signal, for example REDCare's Return Path
Signalling feature, to reset the system following an alarm condition.
40 Bell Fail
This zone type is for bells that have diagnostic capabilities and failure outputs. If activated,
it causes fault for any bell failure condition.
41 Intr Low
This zone type assigns a low priority to a zone in the event of an intruder alarm. The event is
logged as low priority in the event log.
42 Intr High
This zone type assigns a high priority to a zone in the event of an intruder alarm. The event
is logged as high priority in the event log.
43 PSU Fault
This zone type triggers a general fault output and logs a PSU fault in the event log. The fault
is signalled to the ARC as YP when using SIA format and 314 when using CID format.
44 Fault
This zone type triggers a general fault output and logs a fault in the event log. The fault is
signalled to the ARC as IA when using SIA format and 150 when using CID format.