Honeywell Galaxy Flex Installer Manual page 145

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Galaxy Flex Installer Manual
Note: This number must be programmed, even if groups have been
2=Port No.
Enter the port number of the primary destination receiver. The default
value is 10002. Press
Alarm Reporting Secondary IP [56.4.02.3]
The Ethernet module supports signalling to more than one receiver destination. The
Secondary IP defines the receiver destination details for the secondary alarm transmission
path. The destination is made up of an IP address and a port number.
1=IP Address
Enter the IP address of the secondary receiver, and then press
2=Port No.
Enter the port number of the secondary destination receiver. The default
value is 10002. Press
Alarm Reporting Account No. [56.4.02.4]
The account number (4 to 6 digits) identifies the system to the receiver every time a signal is
transmitted.
If groups are enabled the account number you enter in this field is automatically copied to
all groups.
Alarm Reporting Receiver [56.4.02.5]
Use this option to select the paths used for alarm signalling.
1=Single If this option is selected, and a Secondary IP is programmed, the Secondary IP
destination is used in the event of a failure to the Primary IP. A Fail to Comm is
logged against the Primary alarm transmission path.
2=Dual
If this option is selected, and a secondary IP is programmed, events are sent to
both the primary and secondary IP destinations.
Alarm Reporting Alarm Monitoring [56.4.02.6]
Use these options specifically for events that are sent to the Alarm Monitoring application.
1=Trigger The keypad displays the first trigger event and its ON/OFF status (see Table 10
on page 126 for the list of available triggers, and Appendix B for the events that
are controlled by each trigger). The triggers control the transmitted events. If
the trigger is set to ON, any logged events controlled by the trigger are
transmitted.
Select the trigger to be modified using
1=Status option is displayed. Press
2=Groups and then press
1=Status Set the status to 1=ON or 0=OFF. To accept the new status, press
enabled and all groups have a programmed IP address. This is the
IP address used for all system wide events.
to save the programmed number.
ent
to save the programmed number.
ent
.
ent
.
ent
Communications [56]
and
, and then press
A
B
to select this option, or scroll to
ent
.
ent
. The
ent
145