Communications [56]
On selecting the SIA format, you are prompted for the required SIA level. There are five
SIA levels available:
0 (default) – Basic event information with 4 digit account number.
1 – as level 0 plus 6 digit accounts.
2 – as level 1 but with event modifiers.
3 – as level 2 but with text descriptions.
4 – as level 3 but allows control commands to be received by the control panel.
SIA Trigger Events [56.1.01.2.level.1]
When you select the option, the first trigger event and its On/Off status is displayed (see
Table 10 for a list of available triggers). These are the events and alarms that are transmitted
to the ARC or computer. If the trigger status is set to On, an event activation results in
transmission of the event details to the receiver.
The table below shows the list of signalling triggers that are available to the Telecom
module, the USB module, the ISDN module and the Ethernet module.
1=Status
To modify the trigger, select the required trigger type using
program the status to On press
and return to the previous menu level.
Programming the SIA Format with Groups Enabled
If groups have been enabled on the system (refer to Options [63]) the SIA format option
alters, and an additional level is added.
1=Trigger Events
Press
to display the first trigger event. The keypad shows the trigger, the trigger status
ent
and the groups assigned.
1=Status
As described above.
126
No.
Trigger Event
1
PA/Duress
2
Intruder
4
Security
5
Custom Zones
6
Fire
7
Set Fault
8
Omit
9
Tamper
10
Setting
11
Reset/Cancel
Table 10 Trigger Events
, to set it to Off press
1
Galaxy Flex Installer Manual
No.
Trigger Event
12
Modules/Comms
13
Elec Status
14
Menu Access
15
Trouble
16
Log Zone
17
Max Tag
18
Zone Restoral
19
RF Supervision
20
Fault
and
A
. Press
0
ent
and press
. To
B
ent
to save the programming