Honeywell Galaxy Flex Installer Manual page 231

Hide thumbs Also See for Galaxy Flex:
Table of Contents

Advertisement

Galaxy Flex Installer Manual
4.
Close the door. LED 2 switches off and LED 3 switches on. The door must be closed
within the programmed Close Timeout. If the door remains open longer than this, an
alarm is activated.
Card-Held function
4
The MAX
or DCM card can be assigned a single menu option (refer to the MAX Function
[42.1.8] menu option). To activate the function assigned to the MAX
the card in front of the reader for three seconds; all of the LEDs switch on. If a keypad has
been assigned to the MAX function then it displays the details of this option. If no keypad is
assigned, pressing a key on any of the keypads assigned to a common group displays the
card-held function.
Card-Held system setting
4
If the MAX
or DCM card is assigned one of the setting options (options 12, 13, and 16 to
19), the card-held functions starts the setting procedure for the groups assigned to the card.
Note: If Group Restriction is assigned, only the groups that are common to both the MAX
reader and the MAX
To unset the system using the MAX
reader beeps. All of the groups assigned to the card are instantly unset.
4
MAX
Log
Refer to Access Doors [25]
4
MAX
events print out
Refer to Online Print [51.28], and Online Level [51.29].
Downloading the MAX
4
The MAX
/DCM event log can be downloaded to Remote Servicing by using the
MAX/DCM Log copy option in Remote Servicing.
4
user are set/unset.
4
or DCM card, swipe the reader with a valid card. The
4
/ DCM Log
Appendix G: Peripherals
4
or DCM card, hold
4
231

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents