Table B-9: Warranted Characteristics: Triggering System - Tektronix 2212 User Manual

Digital storage & analog oscilloscope
Hide thumbs Also See for 2212:
Table of Contents

Advertisement

Warranted Characteristics
Table B-9: Warranted Characteristics - Triggering System
Name
Description
Sensitivity•, with
Coupling DC
Source
Sensitivity
Internal
0.35 division from DC to
5 MHz, increasing to 1.2 divi-
sion at 60 MHz
External
b
40 mV p-p from DC to
5 MHz, increasing to 150 mV
p-p at 60 MHz
Sensitivity •,
with Coupling AC
Source
Sensitivity
Internal
0.35 division from 50 Hz to
5 MHz, increasing to 1.2 divi-
sion at 60 MHz
External
h
40 mV p-p from 50 Hz to
5 MHz, increasing to 150 mV
p-p at 60 MHz
Sensitivity •, with
Coupling NOISE REJ
Source
Sensitivity
Internal
1.4 division from DC to
5 MHz, increasing to 2.2 divi-
sion at 60 MHz
External
b
160 mV p-p from DC to
5 MHz, increasing to 600 mV
p-p at 60 MHz
Trigger sensitivity is defined as the minimum peak-to-peak sine-wave signal
amplitude required to show the test signal with horizontal jitter of less than
3% of one period (p-p viewed over two seconds),with trigger LEVEL control set
at about midrange level, but not at control extremes.
External trigger signal from a 50
Q
source driving a 50
Q
coaxial cable termi-
nated in 50
Q
at the input connector.
B -18
Rev 12/92
Appendix B: Specifications

Hide quick links:

Advertisement

Table of Contents
loading