Table 5-3: Voltage Cursor Function Readout - Tektronix 2212 User Manual

Digital storage & analog oscilloscope
Hide thumbs Also See for 2212:
Table of Contents

Advertisement

Cursors
5 - 34
The A V2 cursors become the A VY cursors (horizontal lines on the
crt). The
Li
VY cursors represent a crt readout display of a voltage
measurement that depends upon:
-
The distance between the position of the horizontal cursors.
-
The CH 1 VOL TS/DIV switch setting.
-
The probe coding.
RA TIO (11 VX, 11 VY) Function
With the 2212 in X-Y mode, the AVX and AVY measurements will be
displayed as a "RATIO" if one of the VOL TS/DIV switches or both
switches are in the UNCAL position. (With a signal of five screen
divisions corresponding to a ratio of 100%).
CURSOR
Funktion
AV1
AV2
AVX
AVY
AV
Table 5-3: Voltage Cursor Function Readouts
Cursor Readout with
VOL TS/DIV Calibrated
AV1 ........... V
AV2 ........... V
AVX ........... V
AVY ........... V
AV ............. V
Cursor Readout with
VOL TS/DIV UNCALibrated
RATIO .............
%
RATIO ............. %
RATIO ............. %
RATIO ............. %
RATIO .............
%
In Detail

Hide quick links:

Advertisement

Table of Contents
loading