Non-Storage Examples
Small-Angle Phase Difference
Measurement
If the phase difference between the two signals being measured is
small, you can obtain an increased resolution for setting the cur-
sors by using the X10 Horizontal Magnify feature. To make a
small -angle phase difference comparison, use the following proce-
dure (see Figure 3-10):
PH SE 1 8.0°
ZERO
CROSSING
....J--+-+--+--+,f----t--t-:i.o~,::_+---1::.o....,
REFERENCE
SIGNAL
INACTIVE
2V
CURSOR
'-----'----'---'------'----,L--.J......_-L......--l.--'1----'-----'
ACTIVE
CURSOR
ZERO CROSSING C
OMPARISON SIGNAL
Figure 3-10: Small-angle Phase Difference Measurement
Step
1.
Perform steps
1
through 6 of the preceding "Phase
Difference Measurement" procedure to obtain a
five-division display of one cycle of the reference and
comparison signals.