Setting The Filter For Fail-Safe Digital Inputs - Siemens Sinamics G120 Function Manual

Safety integrated
Hide thumbs Also See for Sinamics G120:
Table of Contents

Advertisement

5.12.2.2

Setting the filter for fail-safe digital inputs

With STARTER: Control via onboard terminals
Preconditions
● You are online with STARTER.
● You have selected the extended functions via onboard terminals.
Procedure
To set the filters for the fail-safe digital inputs, proceed as follows:
1. Press the "Safety inputs/outputs" button.
2. Press the "Configuration" button.
3. The discrepancy time (simultaneity monitoring) tolerates signal changes at the fail-safe
digital input that do not occur simultaneously.
4. The input filter suppresses brief signal changes.
5. Close the screen forms.
You have set the filter for the fail-safe digital inputs.
With STARTER: Control via PROFIsafe and onboard terminals
Preconditions
● You are online with STARTER.
● You have selected the extended functions via PROFIsafe and onboard terminals.
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD
Commissioning
5.12 Setting extended functions