Commissioning
5.12 Setting extended functions
Figure 5-34
Parameter
p1051
p1052
p1135
p9501.00
p9501.17
p9509.08
p9564
p9565
p9566
r9714[0]
r9722.12
r9722.13
r9733
196
Feedback signal SDI when the motor is switched offLeft: SDI becomes inactive. Right: SDI
remains active
Switching off the motor when SDI is active (Page 283)
Description
Speed limit RFG positive direction of rotation (Factory setting depends on the Control
Unit)
Speed limit RFG negative direction of rotation (Factory setting depends on the Control
Unit)
OFF3 ramp-down time
1 signal: Enable extended functions.
0 signal: Disable extended functions.
1 signal: Enable SDI
0 signal: Inhibit SDI
1 signal: SDI becomes inactive when the motor is switched off
0 signal: SDI remains active when the motor is switched off
Tolerance (Factory setting: 12 degrees)
Delay time (Factory setting: 100 ms)
Stop response (Factory setting: 1)
0:
STOP A
1:
STOP B
Load-side speed actual value [rpm]
Electrical speed of the motor. For induction motors, the mechanical speed is obtained
from the electrical speed and slip.
1 signal: SDI positive active
1 signal: SDI negative active
Effective setpoint speed limiting
[0]
Positive setpoint limitation
[1]
Negative setpoint limitation
[2]
Absolute setpoint speed limitation
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD