6.6.3.2

SLS without braking ramp monitoring

Function
When you switch from a higher to a lower speed monitoring level (SLS level), the following
takes place:
1. The inverter brakes the motor.
2. Once the delay time has expired, the inverter monitors the speed using the lower speed
monitoring level.
When you switch from one of the lower monitoring level to a higher speed monitoring level,
then the inverter immediately monitors the speed with the higher SLS level.
Figure 6-29
Inverter signal
SLS active
Deselect SLS
SLS level active
Select SLS level
SAM/SBR active
ON/OFF1
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD
Switching between different monitoring thresholds
Parameter
Included in the PROFI‐
safe telegram
r9722.4
r9720.4
r9722.9,
r9722.10
r9720.9,
r9720.10
r9723.16
r0054.0
6.6 Safely Limited Speed (SLS)
Can be interconnec‐
ted with
F-DI
---
---
---
---
---
---
Operation
F-DO
---
---
---
---