Safely Limited Speed (Sls); Overview; Selecting And Deselecting Sls When The Motor Is Switched On - Siemens Sinamics G120 Function Manual

Safety integrated
Hide thumbs Also See for Sinamics G120:
Table of Contents

Advertisement

6.6

Safely Limited Speed (SLS)

6.6.1

Overview

What can you find in this Chapter?
The relevant operating cases for the SLS function are described in this chapter.
Table 6-5
Selecting and de‐
selecting SLS
Switching over
SLS levels when
SLS is active
Discrepancy in
the input signal
Limit value viola‐
tion
Table 6-6
SLS is not active If SLS is not active, then there are no restrictions for switching on and switching off
SLS is active
6.6.2

Selecting and deselecting SLS when the motor is switched on

Selecting SLS when the motor is switched on
As soon as the inverter detects the selection of SLS via a fail-safe digital input or via the
PROFIsafe safe communication, the following happens:
● The inverter limits the speed to a value below the SLS monitoring and brakes the motor
with the OFF3 ramp-down time.
● You can select whether the inverter monitors motor braking using the SMR (Safe Brake
Ramp) function.
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD
Response of the SLS function when the motor is switched on (ON/OFF1 = 1)
Selecting and deselecting SLS when the motor is switched on (Page 253)
Switching over from a higher SLS level to a lower SLS level (and vice versa).
Switching over SLS levels (Page 260)
The fail-safe digital input to select SS1 identifies an error.
Response to a discrepancy when SLS is active (Page 268)
The speed of the motor exceeds the set SLS limit value.
Limit value violation when SLS is active (Page 270)
Switching the motor on and off when SLS is active or not active
Switching on the motor (ON/OFF1 =
0 → 1)
the motor.
If your application requires that SLS al‐
ways remains active, then you must take
into account several special issues when
switching on the motor.
Switching on the motor when SLS
is active (Page 266)
6.6 Safely Limited Speed (SLS)
Switching off the motor (ON/OFF1,
OFF2 or OFF3 = 1 → 0)
The drive response depends on the sig‐
nal that you use to switch off the motor.
Switching off the motor when SLS
is active (Page 264)
Operation
253

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents