Overview Of How To Replace An Inverter - Siemens Sinamics G120 Function Manual

Safety integrated
Hide thumbs Also See for Sinamics G120:
Table of Contents

Advertisement

7.4.1

Overview of how to replace an inverter

Permissible replacement
You must replace the inverter if it continually malfunctions.
In the following cases you will need to replace the inverter:
Replacement:
● Same power rating
● Same firmware version
After you have carried out the replacement, you must restore the inverter's settings.
Risk of injury due to uncontrolled drive motion
Replacing inverters of different types can result in uncontrolled motion of the drive.
● In all cases that are not permitted according to the table above, recommission the drive
Special issue relating to communication via PROFINET: Device replacement without removable data
storage medium
The inverter supports the PROFINET functionality, replacing the device without data storage
medium.
Precondition
The topology of the PROFINET IO system with the IO device involved is configured in your
higher-level control system.
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD
Replacement:
● Same power rating
Higher firmware version
(e.g. replace FW V4.2 by
FW V4.3)
WARNING
after replacing an inverter.
7.4 Replacing the SINAMICS G120C converter
Replacement:
● Same frame size
Higher power rating
● Same firmware version
Inverter and motor must match one another (ratio between
the motor and inverter rated power > 1/4)
Corrective maintenance
Replacement:
● Same frame size
Higher power rating
Higher firmware version
(e.g. replace FW V4.2 by
FW V4.3)
343

Hide quick links: