Operation
6.5 Safe Stop 1 (SS1)
6.5.3

Switching off the motor when SS1 is active

Description
Figure 6-20
If you switch the motor off with the OFF1 or OFF3 command while the SS1 safety function is
active, for example when limit switches are reached, this does not affect how the motor
behaves. SS1 remains active and the inverter brakes the motor until the standstill detection
threshold is reached.
If you switch off the motor with the safety SS1 function active using the OFF2 command, then
the behavior of the drive is dependent on the setting of the SS1 safety function:
● SS1 without speed monitoring:
The inverter switches off the motor torque. The motor then coasts to a standstill. After the
delay time, STO is active.
● SS1 with speed monitoring:
The inverter switches off the motor torque with the STO safety function. The motor then
coasts to a standstill.
Inverter signal
STO active (extended functions)
Deselect SS1 (basic functions)
SS1 active (extended functions)
Deselect SS1 (extended functions)
SAM/SBR active
244
OFF2 command when the SS1 safety function is active (example: SS1 with braking ramp
monitoring)
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Parameters
Included in the PROFI‐
safe telegram
r9722.0
r9773.5
r9722.1
r9720.1
r9723.16
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD
Can be interconnec‐
ted with