Advanced commissioning
8.4 Adapt the default setting of the terminal strip
Parameter
p1023[C]
p1035[C]
p1036[C]
p1055[C]
p1056[C]
p1113[C]
p1201[C]
p2103[C]
p2106[C]
p2112[C]
p2200[C]
p3330[C]
p3331[C]
p3332[C]
Additional information is provided in the parameter list and function diagrams 2210 ff in the List
Manual.
Further information
You can debounce the digital input signal using parameter p0724.
A complete list of binector inputs is provided in the parameter list.
See also
Connections and cables (Page 46)
Safe Torque Off (STO) safety function (Page 178)
8.4.2

Analog inputs as digital inputs

Function description
124
Description
BI: Fixed speed setpoint selection, bit 3
BI: Motorized potentiometer setpoint higher
BI: Motorized potentiometer setpoint lower
BI: Jogging bit 0
BI: Jogging bit 1
BI: Setpoint inversion
BI: Flying restart enable signal source
BI: 1. Acknowledge faults
BI: External fault 1
BI: External alarm 1
BI: Technology controller enable
BI: 2/3 wire control command 1
BI: 2/3 wire control command 2
BI: 2/3 wire control command 3
Overview of the manuals (Page 361)
1
BI: pxxxx
2
7
8
r0722.11
3
6
4
5
r0722.12
Converter with the control units CU240D-2
Operating Instructions, 10/2020, FW V4.7 SP13, A5E34262100B AH
Factory setting
0
Dependent on the converter
Dependent on the converter
Dependent on the converter
Dependent on the converter
Dependent on the converter
1
Dependent on the converter
1
1
0
0
0
0