COMPULSORY VALVE OPERATION CHECK MODE
15.Compulsory Valve Operation
Check Mode
A: OPERATION
1) Prepare the Subaru Select Monitor kit. <Ref. to
EN(H4DOTC)-8, PREPARATION TOOL, General
Description.>
2) Connect the diagnosis cable to Subaru Select
Monitor.
3) Insert the cartridge into Subaru Select Monitor.
<Ref. to EN(H4DOTC)-8, PREPARATION TOOL,
General Description.>
4) Connect the test mode connector (A) at the low-
er portion of instrument panel (on the driver's side).
(A)
5) Connect the Subaru Select Monitor to data link
connector.
(1) Connect the Subaru Select Monitor to data
link connector located in the lower portion of in-
strument panel (on the driver's side).
(2) Connect the diagnosis cable to data link
connector.
CAUTION:
EN-00038
Do not connect scan tools except for the Suba-
ru Select Monitor and OBD-II general scan tool.
6) Turn the ignition switch to ON (engine OFF) and
Subaru Select Monitor switch to ON.
EN-00039
7) On the «Main Menu» display screen, select the
{2. Each System Check} and press the [YES] key.
8) On the «System Selection Menu» display
screen, select the {Engine Control System} and
press the [YES] key.
9) Press the [YES] key after the information of en-
gine type is displayed.
10) On the «Engine Diagnosis» display screen, se-
lect the {System Operation Check Mode} and press
the [YES] key.
11) On the «System Operation Check Mode» dis-
play screen, select the {Actuator ON/OFF Opera-
EN-01288
tion} and press the [YES] key.
12) Select the desired compulsory actuator on the
«Actuator ON/OFF Operation» display screen and
press the [YES] key.
EN(H4DOTC)-49
ENGINE (DIAGNOSTICS)
(A) Power switch
EN-01287
(A)
EN-00040

Hide quick links:

Advertisement