EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES)
5. Purge Control Solenoid Valve
A: REMOVAL
1) Disconnect the ground cable from battery.
2) Disconnect the connector and hose of purge
control solenoid valve, and then remove the purge
control solenoid valve.
PURGE CONTROL SOLENOID VALVE
FU-00009
EC-00014
EC(H4SOw/oOBD)-6
B: INSTALLATION
Install in the reverse order of removal.
Tightening torque:
19 N·m (1.9 kgf-m, 13.7 ft-lb)
NOTE:
Connect the evaporation hoses as shown in the fig-
ure.
A
(A) To fuel pipe
(B) To throttle body
C: INSPECTION
Make sure hoses are not cracked or loose.
EC-00014
B
EC-00015