SMC Networks SMC TigerStack IV SMC6224M Management Manual page 85

Tigerstack 10/100 24/48-port 10/100mbps stackable managed switch
Hide thumbs Also See for SMC TigerStack IV SMC6224M:
Table of Contents

Advertisement

Telnet Port Number – Sets the TCP port number for Telnet on the
switch. (Default: 23)
Login Timeout – Sets the interval that the system waits for a user to
log into the CLI. If a login attempt is not detected within the timeout
interval, the connection is terminated for the session.
(Range: 0-300 seconds; Default: 300 seconds)
Exec Timeout – Sets the interval that the system waits until user input
is detected. If user input is not detected within the timeout interval, the
current session is terminated. (Range: 0-65535 seconds; Default: 600
seconds)
Password Threshold – Sets the password intrusion threshold, which
limits the number of failed logon attempts. When the logon attempt
threshold is reached, the system interface becomes silent for a specified
amount of time (set by the Silent Time parameter) before allowing the
next logon attempt. (Range: 0-120; Default: 3 attempts)
Password
connection is started on a line with password protection, the system
prompts for the password. If you enter the correct password, the
system shows a prompt. (Default: No password)
Login
authentication by a single global password as configured for the
Password parameter, or by passwords set up for specific user-name
accounts. (Default: Local)
2. CLI only.
2
– Specifies a password for the line connection. When a
– Enables password checking at login. You can select
2
B
C
ASIC
ONFIGURATION
3-31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smc6248m6248m int - annexe 1