Barco TransForm A User Manual page 158

Workstation for windows
Hide thumbs Also See for TransForm A:
Table of Contents

Advertisement

Component view
The component view of the DEX shows its information in a hierarchical structure, which means that a component
that is contained in a device is listed as a subentry of this device. This allows you in an OmniBus configuration to
see which video input cards are plugged into which O
nected. With a Processor configuration the P
T
F
A entry. The graphic cards, O
RANS
ORM
The information provided by the component view are basically article numbers of the parts used in T
the version of firmware and controlware as well as configuration values like the PCI slot used for a card and real-
time status values like e.g. temperatures. If a value appears in DEX depends from the used hardware and from
the used OmniBus or Processor configuration.
The table below lists some of the most important values from the extensive list of information given by DEX:
entry
TransForm A
Mainboard
Processor
Memory Array
Memory Device
System BIOS
Voltage Battery
Fan CPU
Temperature
Bandwidth
AGS-3013/3320
AGS-3335
AGS-3359
Fan_BP T left,
middle, right
PSU_BP_rdd
Voltage
Current
Temperature
Backplane 3003
Barco – TransForm A - Workstation for Windows – DOC-3266-2 – Revision 13 – April 2006
MNI
and optional E
ROCESSOR
S
and input cards are direct subentries of T
MNI
CALERS
meaning
properties of interest
P
ROCESSOR
mainboard information (
used processor
overall memory information: memory capacity, memory population
usage of the four individual memory sockets
BIOS type and version
Voltage of the battery
Reading Current voltage
CPU fan
Reading Current revolutions
temperature at one of the 5 sensors on the mainboard
reading Current temperature
current bandwidth consumption in the whole system
Reading bandwidth consumption in Bytes/s
O
B
A18
MNI
US
O
B
A18 with power modules that can be monitored as well
MNI
US
O
B
A12
MNI
US
left, middle or right fan seen from front of the device (right fan is not available
with AGS-3359)
Reading Current revolutions
power module (only available in AGS-3335!)
3 entries per power module for 3.3V, 5V and 12V
Reading Current voltage
3 entries per power module for 3.3V, 5V and 12V
Reading Current current
Temperature of the power module
Reading
backplane of AGS-3013/3320
IDPROM Version, Firmware
B
and again to which Processor this O
US
are commonly represented in the
XTENDERS
only with AGS-3328-2/-3 and AGS-3389-0/-1
_______________________________________________________________
6. Advanced configuration
B
is con-
MNI
US
F
A.
RANS
ORM
F
A,
RANS
ORM
)
6-38

Advertisement

Table of Contents
loading

Table of Contents