Allen-Bradley LOGIX 5000 Reference Manual page 477

Controllers advanced process control and drives and equipment phase and sequence instructions
Hide thumbs Also See for LOGIX 5000:
Table of Contents

Advertisement

Equipment Sequence
SOVR instruction ran successfully. The other four codes indicate that the
instruction did not run successfully and provide additional information about the
reason for the instruction failure.
Available Languages
Ladder Diagram
Function Block
This instruction is not available in Function Block.
Structured Text
SOVR(SequenceName,Command,Result)
Operands
The SOVR instruction uses the following operands.
Operand
Type
Sequence Name
Sequence
Command
Command
Result
DINT
Affects Math Status Flags
No.
Major/Minor Faults
The SOVR instruction cannot trigger a fault, so there are no fault conditions for
this instruction.
Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Format
Description
Name of the Equipment
Equipment Sequence to change to a different state. For
Sequence
example, Make_Product_101.
Name of the command
Command to send to the Equipment Sequence and change
state. Use one of these commands:
• HOLD
• STOP
• ABORT
Immediate tag
For an instruction to return a success or failure code, enter a
DINT tag where the result code is stored. Otherwise, enter 0.
Chapter 8