Allen-Bradley LOGIX 5000 Reference Manual page 231

Controllers advanced process control and drives and equipment phase and sequence instructions
Hide thumbs Also See for LOGIX 5000:
Table of Contents

Advertisement

Process Control Instructions
Output
Data
Parameters
Type
AtuneCV1PV1OutO
BOOL
fLimit
AtuneCV2PV1OutO
BOOL
fLimit
AtuneCV3PV1OutO
BOOL
fLimit
AtuneCV1PV1Mod
BOOL
eInv
AtuneCV2PV1Mod
BOOL
eInv
AtuneCV3PV1Mod
BOOL
eInv
AtuneCV1PV1Win
BOOL
dupFault
AtuneCV2PV1Win
BOOL
dupFault
AtuneCV3PV1Win
BOOL
dupFault
AtuneCV1PV1Step
BOOL
Size0
AtuneCV2PV1Step
BOOL
Size0
AtuneCV3PV1Step
BOOL
Size0
AtuneCV1PV1Limi
BOOL
tsFault
Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Description
Either PV1 or the deadtime-step ahead prediction
of PV1 exceeds PV1TuneLimit during CV1 - PV1
Autotuning. When True, CV1 - PV1 Autotuning is
aborted.
Either PV1 or the deadtime-step ahead prediction
of PV1 exceeds PV1TuneLimit during CV2 - PV1
Autotuning. When True, CV2 - PV1 Autotuning is
aborted.
Either PV1 or the deadtime-step ahead prediction
of PV1 exceeds PV1TuneLimit during CV3 - PV1
Autotuning. When True, CV3 - PV1 Autotuning is
aborted.
The MMC mode was not Manual at start of
Autotuning or the MMC mode was changed from
Manual during CV1 - PV1 Autotuning. When True,
CV1 - PV1 Autotuning is not started or is aborted.
The MMC mode was not Manual at start of
Autotuning or the MMC mode was changed from
Manual during CV2 - PV1 Autotuning. When True,
CV2 - PV1 Autotuning is not started or is aborted.
The MMC mode was not Manual at start of
Autotuning or the MMC mode was changed from
Manual during CV3 - PV1 Autotuning. When True,
CV3 - PV1 Autotuning is not started or is aborted.
CV1WindupHIn or CV1WindupLIn is True at start of
CV1 - PV1 Autotuning or during CV1 - PV1
Autotuning. When True, CV1 - PV1 Autotuning is
not started or is aborted.
CV2WindupHIn or CV2WindupLIn is True at start of
CV2 - PV1 Autotuning or during CV2 - PV1
Autotuning. When True, CV2 - PV1 Autotuning is
not started or is aborted.
CV3WindupHIn or CV3WindupLIn is True at start of
CV3 - PV1 Autotuning or during CV3 - PV1
Autotuning. When True, CV3 - PV1 Autotuning is
not started or is aborted.
CV1StepSizeUsed = 0 at start of CV1 - PV1
Autotuning. When True, CV1 - PV1 Autotuning is
not started.
CV2StepSizeUsed = 0 at start of CV2 - PV1
Autotuning. When True, CV2 - PV1 Autotuning is
not started.
CV3StepSizeUsed = 0 at start of CV3 - PV1
Autotuning. When True, CV3 - PV1 Autotuning is
not started.
CV1LimitsInv and CVManLimiting are True at start
of CV1 - PV1 Autotuning or during CV1 - PV1
Autotuning. When True, CV1 - PV1 Autotuning is
not started or is aborted.
Chapter 1
Values
Bit 1 of AtuneCV1PV1Status
Bit 1 of AtuneCV2PV1Status
Bit 1 of AtuneCV3PV1Status
Bit 2 of AtuneCV1PV1Status
Bit 2 of AtuneCV2PV1Status
Bit 2 of AtuneCV3PV1Status
Bit 3 of AtuneCV1PV1Status
Bit 3 of AtuneCV2PV1Status
Bit 3 of AtuneCV3PV1Status
Bit 4 of AtuneCV1PV1Status
Bit 4 of AtuneCV2PV1Status
Bit 4 of AtuneCV3PV1Status
Bit 5 of AtuneCV1PV1Status
231