Process Control Instructions
Output
Data
Parameters
Type
CV2PV1RespTCTun
REAL
edM
CV3PV1RespTCTun
REAL
edM
CV1PV2RespTCTun
REAL
edM
CV2PV2RespTCTun
REAL
edM
CV3PV2RespTCTun
REAL
edM
CV1PV1RespTCTun
REAL
edF
CV2PV1RespTCTun
REAL
edF
CV3PV1RespTCTun
REAL
edF
CV1PV2RespTCTun
REAL
edF
CV2PV2RespTCTun
REAL
edF
CV3PV2RespTCTun
REAL
edF
AtuneCV1PV1On
BOOL
AtuneCV2PV1On
BOOL
AtuneCV3PV1On
BOOL
AtuneCV1PV1Don
BOOL
e
AtuneCV2PV1Don
BOOL
e
AtuneCV3PV1Don
BOOL
e
AtuneCV1PV1Abor
BOOL
ted
Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Description
The calculated value of the control variable time
constant in medium response speed for CV2 - PV1
after tuning is completed.
The calculated value of the control variable time
constant in medium response speed for CV3 - PV1
after tuning is completed.
The calculated value of the control variable time
constant in medium response speed for CV1 - PV2
after tuning is completed.
The calculated value of the control variable time
constant in medium response speed for CV2 - PV2
after tuning is completed.
The calculated value of the control variable time
constant in medium response speed for CV3 - PV2
after tuning is completed.
The calculated value of the control variable time
constant in fast response speed for CV1 - PV1 after
tuning is completed.
The calculated value of the control variable time
constant in fast response speed for CV2 - PV1 after
tuning is completed.
The calculated value of the control variable time
constant in fast response speed for CV3 - PV1 after
tuning is completed.
The calculated value of the control variable time
constant in fast response speed for CV1 - PV2 after
tuning is completed.
The calculated value of the control variable time
constant in fast response speed for CV2 - PV2 after
tuning is completed.
The calculated value of the control variable time
constant in fast response speed for CV3 - PV2 after
tuning is completed.
Set True when auto tuning for CV1 - PV1 has been
initiated.
Set True when auto tuning for CV2 - PV1 has been
initiated.
Set True when auto tuning for CV3 - PV1 has been
initiated.
Set True when auto tuning for CV1 - PV1 has
completed successfully.
Set True when auto tuning for CV2 - PV1 has
completed successfully.
Set True when auto tuning for CV3 - PV1 has
completed successfully.
Set True when auto tuning for CV1 - PV1 has been
aborted by user or due to errors that occurred
during the auto tuning operation.