Allen-Bradley LOGIX 5000 Reference Manual page 228

Controllers advanced process control and drives and equipment phase and sequence instructions
Hide thumbs Also See for LOGIX 5000:
Table of Contents

Advertisement

Chapter 1
Process Control Instructions
228
Output
Data
Parameters
Type
CV2PV2GainTuned REAL
CV3PV2GainTuned REA:
CV1PV1TCTuned
REAL
CV2PV1TCTuned
REAL
CV3PV1TCTuned
REAL
CV1PV2TCTuned
REAL
CV2PV2TCTuned
REAL
CV3PV2TCTuned
REAL
CV1PV1DTTuned
REAL
CV2PV1DTTuned
REAL
CV3PV1DTTuned
REAL
CV1PV2DTTuned
REAL
CV2PV2DTTuned
REAL
CV3PV2DTTuned
REAL
CV1PV1RespTCTun
REAL
edS
CV2PV1RespTCTun
REAL
edS
CV3PV1RespTCTun
REAL
edS
CV1PV2RespTCTun
REAL
edS
CV2PV2RespTCTun
REAL
edS
CV3PV2RespTCTun
REAL
edS
CV1PV1RespTCTun
REAL
edM
Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Description
The calculated value of the internal model gain for
CV2 - PV2 after tuning is completed.
The calculated value of the internal model gain for
CV3 - PV2 after tuning is completed.
The calculated value of the internal model time
constant for CV1 - PV1 after tuning is completed.
The calculated value of the internal model time
constant for CV2 - PV1 after tuning is completed.
The calculated value of the internal model time
constant for CV3 - PV1 after tuning is completed.
The calculated value of the internal model time
constant for CV1 - PV2 after tuning is completed.
The calculated value of the internal model time
constant for CV2 - PV2 after tuning is completed.
The calculated value of the internal model time
constant for CV3 - PV2 after tuning is completed.
The calculated value of the internal model
deadtime for CV1 - PV1 after tuning is completed.
The calculated value of the internal model
deadtime for CV2 - PV1 after tuning is completed.
The calculated value of the internal model
deadtime for CV3 - PV1 after tuning is completed.
The calculated value of the internal model
deadtime for CV1 - PV2 after tuning is completed.
The calculated value of the internal model
deadtime for CV2 - PV2 after tuning is completed.
The calculated value of the internal model
deadtime for CV3 - PV2 after tuning is completed.
The calculated value of the control variable time
constant in slow response speed for CV1 - PV1 after
tuning is completed.
The calculated value of the control variable time
constant in slow response speed for CV2 - PV1 after
tuning is completed.
The calculated value of the control variable time
constant in slow response speed for CV3 - PV1 after
tuning is completed.
The calculated value of the control variable time
constant in slow response speed for CV1 - PV2 after
tuning is completed.
The calculated value of the control variable time
constant in slow response speed for CV2 - PV2 after
tuning is completed.
The calculated value of the control variable time
constant in slow response speed for CV3 - PV2 after
tuning is completed.
The calculated value of the control variable time
constant in medium response speed for CV1 - PV1
after tuning is completed.
Values