Chapter 1
Process Control Instructions
236
Output
Data
Parameters
Type
Status3CV3
DINT
InstructFault
BOOL
PV1Faulted
BOOL
PV2Faulted
BOOL
PV1SpanInv
BOOL
PV2SpanInv
BOOL
SP1ProgInv
BOOL
SP2ProgInv
BOOL
SP1OperInv
BOOL
SP2OperInv
BOOL
SP1LimitsInv
BOOL
SP2LimitsInv
BOOL
SampleTimeTooS
BOOL
mall
PV1FactorInv
BOOL
PV2FactorInv
BOOL
TimingModeInv
BOOL
RTSMissed
BOOL
RTSTimeInv
BOOL
RTSTimeStampInv BOOL
DeltaTInv
BOOL
CV1Faulted
BOOL
CV2Faulted
BOOL
CV3Faulted
BOOL
CV1HandFBFaulte
BOOL
d
CV2HandFBFaulte
BOOL
d
Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Description
Additional bit mapped CV3 status for the function
block. A value of 0 indicates that no faults have
occurred.
The function block has generated a fault. Indicates
state of bits in Status1, Status2, and Status3CV(n),
where (n) can be 1, 2, or 3.
Process variable PV1 health bad.
Process variable PV2 health bad.
The span of PV1 inValid, PV1EUMax < PV1EUMin.
The span of PV2 inValid, PV2EUMax < PV2EUMin.
SP1Prog < SP1LLimit or > SP1HLimit. Limit value
used for SP1.
SP2Prog < SP2LLimit or > SP2HLimit. Limit value
used for SP2.
SP1Oper < SP1LLimit or > SP1HLimit. Limit value
used for SP1.
SP2Oper < SP2LLimit or > SP2HLimit. Limit value
used for SP2.
Limits inValid: SP1LLimit < PV1EUMin, SP1HLimit
> PV1EUMax, or SP1HLimit < SP1LLimit. If
SP1HLimit < SP1LLimit, then limit value by using
SP1LLimit.
Limits inValid: SP2LLimit < PV2EUMin, SP2HLimit
> PV2EUMax, or SP2HLimit < SP2LLimit. If
SP2HLimit < SP2LLimit, then limit value by using
SP2LLimit.
Model DeadTime / DeltaT must be less than or
equal to 200.
Entered value for Factor1 < 0.
Entered value for Factor2 < 0.
Entered TimingMode inValid. If the current mode is
not Override or Hand then set to Manual mode.
Only used when in Real Time Sampling mode. Is
TRUE when ABS(DeltaT – RTSTime) > 1
millisecond.
Entered RTSTime inValid.
RTSTimeStamp inValid. If the current mode is not
Override or Hand, then set to Manual mode.
DeltaT inValid. If the current mode is not Override
or Hand then set to Manual mode.
Control variable CV1 health bad.
Control variable CV2 health bad.
Control variable CV3 health bad.
CV1 HandFB value health bad.
CV2 HandFB value health bad.
Values
Bit 0 of Status1
Bit 1 of Status1
Bit 2 of Status1
Bit 3 of Status1
Bit 4 of Status1
Bit 5 of Status1
Bit 6 of Status1
Bit 7 of Status1
Bit 8 of Status1
Bit 9 of Status1
Bit 10 of Status1
Bit 11 of Status1
Bit 12 of Status1
Bit 13 of Status1
Bit 27 of Status2
Bit 28 of Status2.
Bit 29 of Status2.
Bit 30 of Status2.
Bit 31 of Status2.
Bit 0 of Status3CV1
Bit 0 of Status3CV2
Bit 0 of Status3CV3
Bit 1 of Status3CV1
Bit 1 of Status3CV2