Process Control Instructions
222
Input Parameters Data
Type
CV1PV2ModelInit
BOOL
CV2PV2ModelInit
BOOL
CV3PV2ModelInit
BOOL
PV1Factor
REAL
PV2Factor
AtuneCV1Start
BOOL
AtuneCV2Start
BOOL
AtuneCV3Start
BOOL
AtuneCV1PV1UseM
BOOL
odel
AtuneCV2PV1UseM
BOOL
odel
AtuneCV3PV1UseM
BOOL
odel
AtuneCV1PV2UseM
BOOL
odel
AtuneCV2PV2UseM
BOOL
odel
Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Description
Internal model initialization switch for CV1 - PV2.
Refer to Function Block Attributes.
Internal model initialization switch for CV2 - PV2.
Refer to Function Block Attributes.
Internal model initialization switch for CV3 - PV2.
Refer to Function Block Attributes.
Non-integrating model approximation factor for
PV1. Only used for integrating process types.
Non-integrating model approximation factor for
PV2. Only used for integrating process types.
Start Autotune request for CV1. Set True to
initiate auto tuning of the CV1 output for both
PV1 and PV2. Ignored when CV1 is not in Manual
mode. The function block resets the input to
FALSE.
Start Autotune request for CV2. Set True to
initiate auto tuning of the CV2 output for both
PV1 and PV2. Ignored when CV2 is not in Manual
mode. The function block resets the input to
FALSE.
Start Autotune request for CV3. Set True to
initiate auto tuning of the CV3 output for both
PV1 and PV2. Ignored when CV3 is not in Manual
mode. The function block resets the input to
FALSE.
Use Autotune model request for CV1 - PV1. Set
True to replace the current model parameters
with the calculated Autotune model parameters.
The function block resets the input parameter to
FALSE.
Use Autotune model request for CV2 - PV1. Set
True to replace the current model parameters
with the calculated Autotune model parameters.
The function block resets the input parameter to
FALSE.
Use Autotune model request for CV3 - PV1. Set
True to replace the current model parameters
with the calculated Autotune model parameters.
The function block resets the input parameter to
FALSE.
Use Autotune model request for CV1 - PV2. Set
True to replace the current model parameters
with the calculated Autotune model parameters.
The function block resets the input parameter to
FALSE.
Use Autotune model request for CV2 - PV2. Set
True to replace the current model parameters
with the calculated Autotune model parameters.
The function block resets the input parameter to
FALSE.
Values
Default = FALSE
Default = FALSE
Default = FALSE
Default = 100
Default = 100
Default = FALSE
Default = FALSE
Default = FALSE
Default = FALSE
Default = FALSE
Default = FALSE
Default = FALSE
Default = FALSE