Chapter 1
Process Control Instructions
232
Output
Data
Parameters
Type
AtuneCV2PV1Limi
BOOL
tsFault
AtuneCV3PV1Limi
BOOL
tsFault
AtuneCV1PV1InitF
BOOL
ault
AtuneCV2PV1InitF
BOOL
ault
AtuneCV3PV1InitF
BOOL
ault
AtuneCV1PV1EUSp
BOOL
anChanged
AtuneCV2PV1EUSp
BOOL
anChanged
AtuneCV3PV1EUSp
BOOL
anChanged
AtuneCV1PV1Chan
BOOL
ged
AtuneCV2PV1Chan
BOOL
ged
AtuneCV3PV1Chan
BOOL
ged
AtuneCV1PV1Time
BOOL
out
AtuneCV2PV1Time
BOOL
out
Rockwell Automation Publication 1756-RM006K-EN-P - November 2018
Description
CV2LimitsInv and CVManLimiting are True at start
of CV2 - PV1 Autotuning or during CV2 - PV1
Autotuning. When True, CV2 _PV1 Autotuning is
not started or is aborted.
CV3LimitsInv and CVManLimiting are True at start
of CV3 - PV1 Autotuning or during CV3 - PV1
Autotuning. When True, CV3 - PV1 Autotuning is
not started or is aborted.
CV1Initializing is True at start of CV1 - PV1
Autotuning or during CV1 - PV1 Autotuning. When
True, CV1 - PV1 Autotuning is not started or is
aborted.
CV2Initializing is True at start of CV2 - PV1
Autotuning or during CV2 - PV1 Autotuning. When
True, CV2 - PV1 Autotuning is not started or is
aborted.
CV3Initializing is True at start of CV3 - PV1
Autotuning or during CV3 - PV1 Autotuning. When
True, CV3 - PV1 Autotuning is not started or is
aborted.
CV1EUSpan or PV1EUSpan changes during CV1 -
PV1 Autotuning. When True, CV1 - PV1 Autotuning
is aborted.
CV2EUSpan or PV1EUSpan changes during CV2 -
PV1 Autotuning. When True, CV2 - PV1 Autotuning
is aborted.
CV3EUSpan or PV1EUSpan changes during CV3 -
PV1 Autotuning. When True, CV3 - PV1 Autotuning
is aborted.
CV1Oper is changed when in Operator control or
CV1Prog is changed when in Program control or
CV1 becomes high/low or ROC limited during CV1 -
PV1 Autotuning. When True, CV1 - PV1 Autotuning
is aborted.
CV2Oper is changed when in Operator control or
CV2Prog is changed when in Program control or
CV2 becomes high/low or ROC limited during CV2 -
PV1 Autotuning. When True, CV2 - PV1 Autotuning
is aborted.
CV3Oper is changed when in Operator control or
CV3Prog is changed when in Program control or
CV3 becomes high/low or ROC limited during CV3 -
PV1 Autotuning. When True, CV3 - PV1 Autotuning
is aborted.
Elapsed time is greater then PV1AtuneTimeLimit
since step test is started. When True, CV1 - PV1
Autotuning is aborted.
Elapsed time is greater then PV1AtuneTimeLimit
since step test is started. When True, CV2 - PV1
Autotuning is aborted.
Values
Bit 5 of AtuneCV2PV1Status
Bit 5 of AtuneCV3PV1Status
Bit 6 of AtuneCV1PV1Status
Bit 6 of AtuneCV2PV1Status
Bit 6 of AtuneCV3PV1Status
Bit 7 of AtuneCV1PV1Status
Bit 7 of AtuneCV2PV1Status
Bit 7 of AtuneCV3PV1Status
Bit 8 of AtuneCV1PV1Status
Bit 8 of AtuneCV2PV1Status
Bit 8 of AtuneCV3PV1Status
Bit 9 of AtuneCV1PV1Status
Bit 9 of AtuneCV2PV1Status