[:INPut]:VOLTage:CONFig[:ALL]
Function
Collectively sets the valid voltage range of all
elements.
[:INPut]:VOLTage:CONFig[:ALL]
Syntax
{ALL|<Voltage>[,<Voltage>][,
<Voltage>]...}
ALL = All ranges are valid.
• When the crest factor is set to 3:
<Voltage> = 1.5 V, 3 V, 6 V, 10 V, 15 V, 30 V,
60 V, 100 V, 150 V, 300 V, 600 V, 1000 V
• When the crest factor is set to 6:
<Voltage> = 0.75 V, 1.5 V, 3 V, 5 V, 7.5 V, 15 V,
30 V, 50 V, 75 V, 150 V, 300 V, 500 V
:INPUT:VOLTAGE:CONFIG:ALL ALL
Example
:INPUT:VOLTAGE:CONFIG:ALL
1000,300,100,30,10
Description In the parameters, list all the voltage ranges that
you want to enable. To enable all the ranges,
specify the parameter "ALL."
[:INPut]:VOLTage:CONFig:ELEMent<x>
Function
Sets or queries the valid voltage ranges of the
specified element.
[:INPut]:VOLTage:CONFig:ELEMent<x>
Syntax
{ALL|<Voltage>[,<Voltage>][,
<Voltage>]...}
[:INPut]:VOLTage:CONFig:ELEMent<x>?
<x> = 1 to 6 (element)
ALL = All ranges are valid.
<Voltage> = See [:INPut]:VOLTage:
CONFig
[:ALL]
:INPUT:VOLTAGE:CONFIG:ELEMENT1 ALL
Example
:INPUT:VOLTAGE:CONFIG:ELEMENT1? ->
:INPUT:VOLTAGE:CONFIG:ELEMENT1 ALL
:INPUT:VOLTAGE:CONFIG:ELEMENT1
1000,300,100,30,10
:INPUT:VOLTAGE:CONFIG:ELEMENT1? ->
:INPUT:VOLTAGE:CONFIG:ELEMENT1
1.0000E+03,300.0E+00,100.0E+00,30.0E
+00,10.0E+00
Description In the parameters, list all the voltage ranges that
you want to enable. To enable all the ranges,
specify the parameter "ALL."
[:INPut]:VOLTage:POJump?
Function
Queries the jump destination ranges of all
elements that are used when a voltage peak
over-range occurs.
[:INPut]:VOLTage:POJump?
Syntax
IM WT1801-17EN
[:INPut]:VOLTage:POJump[:ALL]
Function
Collectively sets the jump destination range of all
elements that is used when a voltage peak over-
range occurs.
[:INPut]:VOLTage:POJump[:ALL]
Syntax
{OFF|<Voltage>}
OFF = No jump destination voltage
range
• When the crest factor is set to 3:
<Voltage> = 1.5 V, 3 V, 6 V, 10 V, 15 V, 30 V,
60 V, 100 V, 150 V, 300 V, 600 V, 1000 V
• When the crest factor is set to 6:
<Voltage> = 0.75 V, 1.5 V, 3 V, 5 V, 7.5 V, 15 V,
30 V, 50 V, 75 V, 150 V, 300 V, 500 V
:INPUT:VOLTAGE:POJUMP:ALL OFF
Example
[:INPut]:VOLTage:POJump:ELEMent<x>
Function
Sets or queries the jump destination range of the
specified element that is used when a voltage
peak over-range occurs.
[:INPut]:VOLTage:POJump:ELEMent<x>
Syntax
{OFF|<Voltage>}
[:INPut]:VOLTage:POJump:ELEMent<x>?
<x> = 1 to 6 (element)
OFF = No jump destination voltage
range
<Voltage> = See [:INPut]:VOLTage:
POJump[:ALL]
:INPUT:VOLTAGE:POJUMP:ELEMENT1 1000V
Example
:INPUT:VOLTAGE:POJUMP:ELEMENT1? ->
:INPUT:VOLTAGE:POJUMP:
ELEMENT1 1.0000E+03
[:INPut]:VOLTage:RANGe?
Function
Queries the voltage ranges of all elements.
[:INPut]:VOLTage:RANGe?
Syntax
[:INPut]:VOLTage:RANGe[:ALL]
Function
Collectively sets the voltage range of all elements.
[:INPut]:VOLTage:RANGe[:ALL]
Syntax
{<Voltage>}
• When the crest factor is set to 3:
<Voltage> = 1.5 V, 3 V, 6 V, 10 V, 15 V, 30 V,
60 V, 100 V, 150 V, 300 V, 600 V, 1000 V
• When the crest factor is set to 6:
<Voltage> = 0.75 V, 1.5 V, 3 V, 5 V, 7.5 V, 15 V,
30 V, 50 V, 75 V, 150 V, 300 V, 500 V
:INPUT:VOLTAGE:RANGE:ALL 1000V