YOKOGAWA WT1800 User Manual page 47

Precision power analyzer communication interface
Hide thumbs Also See for WT1800:
Table of Contents

Advertisement

Command
WAVeform Group
:WAVeform?
:WAVeform:BYTeorder
:WAVeform:END
:WAVeform:FORMat
:WAVeform:HOLD
:WAVeform:LENGth?
:WAVeform:SEND?
:WAVeform:SRATe?
:WAVeform:STARt
:WAVeform:TRACe
:WAVeform:TRIGger?
Common Command Group
*CAL?
*CLS
*ESE
*ESR?
*IDN?
*OPC
*OPC?
*OPT?
*RST
*SRE
*STB?
*TRG
*TST?
*WAI
IM WT1801-17EN
Function
Queries all waveform display data output settings.
Sets or queries the output byte order of the waveform display data (FLOAT
format) that is transmitted by the :WAVeform:SEND? command.
Sets or queries the output end point of the waveform display data that is
transmitted by the :WAVeform:SEND? command.
Sets or queries the format of the waveform display data that is transmitted by
the :WAVeform:SEND? command.
Sets or queries the on/off (hold/release) status of the waveform display data
hold feature for all waveforms.
Queries the total number of points of the waveform specified by the
:WAVeform:TRACe command.
Queries the waveform display data specified by the :WAVeform:TRACe
command.
Queries the sample rate of the acquired waveform.
Sets or queries the output start point of the waveform display data that is
transmitted by the :WAVeform:SEND? command.
Sets or queries the target waveform for the :WAVeform:SEND? command.
Queries the trigger position of the acquired waveform.
Executes zero calibration (zero-level compensation, the same operation as
pressing CAL—SHIFT+SINGLE) and queries the result.
Clears the standard event register, extended event register, and error queue. 5-102
Sets or queries the standard event enable register.
Queries and clears the standard event register.
Queries the instrument model.
Sets bit 0 (the OPC bit) of the standard event register to 1 upon the
completion of the specified overlap command.
Returns ASCII code 1 if the specified overlap command has finished.
Queries the installed options.
Initializes the settings.
Sets or queries the service request enable register.
Queries the status byte register.
Executes single measurement (the same operation as when SINGLE is
pressed).
Performs a self-test and queries the result.
Holds the execution of the subsequent command until the completion of the
specified overlap command.
5.1 List of Commands
Page
5-100
5-100
5-100
5-100
5-100
5-100
5-101
5-101
5-101
5-101
5-101
5-102
5-102
5-102
5-102
5-102
5-103
5-103
5-103
5-103
5-103
5-103
5-104
5-104
5-15
1
2
3
4
5
6
App
Index

Advertisement

Table of Contents
loading

Table of Contents