YOKOGAWA WT1800 User Manual page 45

Precision power analyzer communication interface
Hide thumbs Also See for WT1800:
Table of Contents

Advertisement

Command
:NUMeric:LIST:SELect
:NUMeric:LIST:VALue?
:NUMeric:NORMal?
:NUMeric[:NORMal]:CLEar
:NUMeric[:NORMal]:DELete
:NUMeric[:NORMal]:ITEM<x>
:NUMeric[:NORMal]:NUMber
:NUMeric[:NORMal]:PRESet
:NUMeric[:NORMal]:VALue?
RATE Group
:RATE
STATus Group
:STATus?
:STATus:CONDition?
:STATus:EESE
:STATus:EESR?
:STATus:ERRor?
:STATus:FILTer<x>
:STATus:QENable
:STATus:QMESsage
:STATus:SPOLl?
STORe Group
:STORe?
:STORe:COUNt
:STORe:FILE?
:STORe:FILE:ANAMing
:STORe:FILE:CDIRectory
:STORe:FILE:CONVert?
:STORe:FILE:CONVert:ABORt
:STORe:FILE:CONVert:AUTO
:STORe:FILE:CONVert:EXECute
:STORe:FILE:DRIVe
:STORe:FILE:FREE?
:STORe:FILE:NAME
:STORe:FILE:PATH?
:STORe:INTerval
:STORe:NUMeric?
:STORe:NUMeric:ITEM
:STORe:NUMeric:NORMal?
:STORe:NUMeric[:NORMal]:ALL
:STORe:NUMeric[:NORMal]:
{ELEMent<x>|SIGMA|SIGMB|SIGMC}
:STORe:NUMeric[:NORMal]:<Functi
on>
IM WT1801-17EN
Function
Sets or queries the output components of the harmonic measurement
numeric list data.
Queries the harmonic measurement numeric list data.
Queries all numeric data output settings.
Clears numeric data output items (sets the items to NONE).
Deletes numeric data output items.
Sets or queries the specified numeric data output item (function, element,
and harmonic order).
Sets or queries the number of numeric data items that are transmitted by the
:NUMeric[:NORMal]:VALue? command.
Presets the numeric data output item pattern.
Queries the numeric data.
Sets or queries the data update rate.
Queries all the settings for the communication status feature.
Queries the contents of the condition register.
Sets or queries the extended event enable register.
Queries the contents of the extended event register and clears the register.
Queries the error code and message of the last error that has occurred (top
of the error queue).
Sets or queries the transition filter.
Sets or queries whether messages other than errors will be stored to the
error queue (ON/OFF).
Sets or queries whether message information will be attached to the
response to the STATus:ERRor? query (ON/OFF).
Executes serial polling.
Queries all numeric data storage settings.
Sets or queries the storage count.
Queries all settings related to the saving of the data stored in the WT1800 to
files.
Sets or queries the auto naming feature for saving stored numeric data to
files.
Changes the directory that stored numeric data is saved to.
Queries all settings related to the conversion of stored numeric data files into
CSV format.
Aborts the conversion of a numeric data file to CSV format.
Sets or queries the on/off status of the automatic conversion of stored
numeric data files to CSV format.
Converts the specified stored numeric data file to CSV format.
Sets the drive that stored numeric data is saved to.
Queries the free space (in bytes) on the drive that the stored numeric data is
saved to.
Sets or queries the name of the file that stored numeric data is saved to.
Queries the absolute path of the directory that the stored numeric data is
saved to.
Sets or queries the storage interval.
Queries all numeric data storage item settings.
Sets or queries the numeric data storage item selection method.
Queries all numeric data storage item settings (for the manual selection
method).
Collectively sets the on/off status of the output of all element functions when
numeric data is stored.
Sets or queries the on/off status of the output of the specified element or
wiring unit ΣA, ΣB, or ΣC when numeric data is stored.
Sets or queries the on/off status of the specified function's output when
numeric data is stored.
5.1 List of Commands
Page
5-84
5-85
5-85
5-85
5-85
5-86
5-86
5-86
5-86
5-92
5-93
5-93
5-93
5-93
5-93
5-93
5-93
5-93
5-93
5-94
5-94
5-94
5-94
5-94
5-94
5-94
5-94
5-94
5-94
5-94
5-95
5-95
5-95
5-95
5-95
5-95
5-95
5-95
5-95
5-13
1
2
3
4
5
6
App
Index

Advertisement

Table of Contents
loading