:DISPlay:TRENd:TDIV
Function
Sets or queries the trend horizontal axis (T/div).
:DISPlay:TRENd:TDIV {<NRf>,<NRf>,
Syntax
<NRf>}
:DISPlay:TRENd:TDIV?
{<NRf>,<NRf>,<NRf>} = 0, 0, 3 to
24, 0, 0
First <NRf> = 1, 3, 6, 12, 24 (hours)
Second <NRf> = 1, 3, 6, 10, 30
(minutes)
Third <NRf> = 3, 6, 10, 30 (seconds)
:DISPLAY:TREND:TDIV 0,0,3
Example
:DISPLAY:TREND:TDIV? ->
:DISPLAY:TREND:TDIV 0,0,3
Description Set the three <NRf>'s so that one <NRf> is a
non-zero value and the other two are zero.
:DISPlay:VECTor?
Function
Queries all vector display settings.
:DISPlay:VECTor?
Syntax
Description The vector display is only available on models
with the harmonic measurement (/G5 or /G6)
option.
:DISPlay:VECTor:FORMat
Function
Sets or queries the display format of all vectors.
:DISPlay:VECTor:FORMat {SINGle|DUAL}
Syntax
:DISPlay:VECTor:FORMat?
:DISPLAY:VECTOR:FORMAT SINGLE
Example
:DISPLAY:VECTOR:FORMAT? ->
:DISPLAY:VECTOR:FORMAT SINGLE
:DISPlay:VECTor:ITEM<x>?
Function
Queries all settings for the specified vector.
:DISPlay:VECTor:ITEM<x>?
Syntax
<x> = 1 or 2 (item number)
:DISPlay:VECTor:ITEM<x>:OBJect
Function
Sets or queries the wiring unit that is displayed
using the specified vector.
:DISPlay:VECTor:ITEM<x>:
Syntax
OBJect {<Element>}
:DISPlay:VECTor:ITEM<x>:OBJect?
<x> = 1 or 2 (item number)
<Element> = {<NRf>|SIGMa|SIGMB|
SIGMC}(<NRf> = 1 to 6)
:DISPLAY:VECTOR:ITEM1:OBJECT SIGMA
Example
:DISPLAY:VECTOR:ITEM1:OBJECT? ->
:DISPLAY:VECTOR:ITEM1:OBJECT SIGMA
IM WT1801-17EN
:DISPlay:VECTor:ITEM<x>:{UMAG|IMAG}
Function
Sets or queries the voltage or current zoom factor
for the vector display.
:DISPlay:VECTor:ITEM<x>:{UMAG|IMAG}
Syntax
{<NRf>}
:DISPlay:VECTor:ITEM<x>:{UMAG|IMAG}?
<x> = 1 or 2 (item number)
<NRf> = 0.100 to 100.000
:DISPLAY:VECTOR:ITEM1:UMAG 1
Example
:DISPLAY:VECTOR:ITEM1:UMAG? ->
:DISPLAY:VECTOR:ITEM1:UMAG 1.000
:DISPlay:VECTor:NUMeric
Function
Sets or queries the on/off status of the numeric
data display on the vector display.
:DISPlay:VECTor:NUMeric {<Boolean>}
Syntax
:DISPlay:VECTor:NUMeric?
:DISPLAY:VECTOR:NUMERIC ON
Example
:DISPLAY:VECTOR:NUMERIC? ->
:DISPLAY:VECTOR:NUMERIC 1
:DISPlay:WAVE?
Function
Queries all waveform display settings.
:DISPlay:WAVE?
Syntax
:DISPlay:WAVE:ALL
Function
Collectively sets the on/off status of all waveform
displays.
:DISPlay:WAVE:ALL {<Boolean>}
Syntax
:DISPLAY:WAVE:ALL ON
Example
:DISPlay:WAVE:FORMat
Function
Sets or queries the display format of all
waveforms.
:DISPlay:WAVE:FORMat {SINGle|DUAL|
Syntax
TRIad|QUAD|HEXa}
:DISPlay:WAVE:FORMat?
:DISPLAY:WAVE:FORMAT SINGLE
Example
:DISPLAY:WAVE:FORMAT? ->
:DISPLAY:WAVE:FORMAT SINGLE
:DISPlay:WAVE:GRATicule
Function
Sets or queries the graticule (grid) type.
:DISPlay:WAVE:GRATicule {GRID|FRAMe|
Syntax
CROSshair}
:DISPlay:WAVE:GRATicule?
:DISPLAY:WAVE:GRATICULE GRID
Example
:DISPLAY:WAVE:GRATICULE? ->
:DISPLAY:WAVE:GRATICULE GRID