Solution; C1005: Zu Communication Error; C1130: 1St Stopper Motor Drive Failure - Olivetti ZU-603 Service Manual

Option printer
Table of Contents

Advertisement

8. Malfunction code
8.2

Solution

8.2.1

C1005: ZU communication error

ZU control board (ZUCB)
Step
Disconnect and then connect the power
cord. Turn OFF the main power switch, wait
1
for 10 sec. or more, and turn ON the main
power switch.
Rewrite firmware using the compact flash
2
card.
3
Change ZUCB
8.2.2

C1130: 1st stopper motor drive failure

1st stopper motor (M2)
1st stopper home sensor (PS3)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of each motor for
2
proper drive coupling, and correct as nec-
essary.
3
PS3 I/O check, sensor check
4
M2 operation check
5
Change M2
6
Change ZUCB
56
Relevant electrical parts
Action
Relevant electrical parts
Action
Service Manual
Field Service Ver. 2.0 May 2008
WIRING DIAGRAM
Control signal
ZU control board (ZUCB)
WIRING DIAGRAM
Control signal
ZUCB CN4-11 (ON)
ZUCB CN15-1 to 6
Location
(Electrical
component)
Location
(Electrical
component)
C-5
C-3
Y107910-0

Advertisement